Hoshizaki KM-1301SAJ/3 Service Manual

Hoshizaki KM-1301SAJ/3 Service Manual

Modular crescent cuber
Hide thumbs Also See for KM-1301SAJ/3:
Table of Contents

Advertisement

Service Manual
Modular Crescent Cuber
Models
KM-1301SAJ/3, SWJ/3, SRJ/3
KM-1601SAJ/3, SWJ/3, SRJ/3
KM-1900SAJ/3, SWJ/3, SRJ/3
KM-2200SWJ3, SRJ3
KM-2600SWJ3, SRJ3
hoshizakiamerica.com
Number: 73216
Issued: 10-27-2017
Revised: 5-30-2018

Advertisement

Table of Contents
loading

Summary of Contents for Hoshizaki KM-1301SAJ/3

  • Page 1 Service Manual Modular Crescent Cuber Models KM-1301SAJ/3, SWJ/3, SRJ/3 KM-1601SAJ/3, SWJ/3, SRJ/3 KM-1900SAJ/3, SWJ/3, SRJ/3 KM-2200SWJ3, SRJ3 KM-2600SWJ3, SRJ3 Number: 73216 hoshizakiamerica.com Issued: 10-27-2017 Revised: 5-30-2018...
  • Page 2 Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, send an e-mail message, or write to the Hoshizaki Technical Support Department for assistance. Phone: 1-800-233-1940; (770) 487-2331 Fax: 1-800-843-1056;...
  • Page 3: Table Of Contents

    IMPORTANT This manual should be read carefully before the appliance is serviced. Read the warnings and guidelines contained in this manual carefully as they provide essential information for the continued safe use, service, and maintenance of the appliance. Retain this manual for any further reference that may be necessary. CONTENTS Important Safety Information ....................
  • Page 4 III. Controls and Adjustments ....................39 A. Control Board Layout ....................40 B. LED Lights and Audible Alarm Safeties ............... 41 C. Settings and Adjustments .................... 42 1. Default Dip Switch Settings ..................42 2. Harvest Time (S4 dip switch 1 & 2)................ 43 3.
  • Page 5 B. Wiring Diagrams ......................79 1. Single Phase Models ..................... 79 a) KM-1301S_J ..................... 79 b) KM-1601S_J ..................... 80 c) KM-1900S_J ..................... 81 2. Three Phase Models ....................82 a) KM-1301S_J3 ....................82 b) KM-1601S_J3 ....................83 c) KM-1900_2200_2600S_J3 ................84...
  • Page 6: Important Safety Information

    Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, damage to the appliance, or damage to property. WARNING Indicates a hazardous situation which could result in death or serious injury.
  • Page 7 WARNING, continued • The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. •...
  • Page 8: Construction And Water/Refrigeration Circuit Diagram

    I. Construction and Water/Refrigeration Circuit Diagram A. KM Construction 1. Air-Cooled Models (SAJ/3) Spray Tubes Low-Side Service Valve Inlet Water Valve High-Side Service Valve Evaporator Assembly Thermostatic Expansion Valves Water Supply Inlet Junction Box Hot Gas Valve Check Valves (refrigeration) Cleaning Valve Condenser Control Box...
  • Page 9: Water-Cooled Models (Swj/3)

    2. Water-Cooled Models (SWJ/3) Spray Tubes Low-Side Service Valve Inlet Water Valve High-Side Service Valve Evaporator Assembly Thermostatic Expansion Valves Water Supply Inlet Junction Box Hot Gas Valve Check Valves (refrigeration) Water-Cooled Condenser Cleaning Valve Check Valve (water) Water Pump Water Regulating Float Switch Valve...
  • Page 10: Remote Models (Km-1301Srj/3 And Km-1601Srj/3)

    3. Remote Models (KM-1301SRJ/3 and KM-1601SRJ/3) Inlet Water Valve Low-Side Service Valve Spray Tubes High-Side Service Valve Evaporator Assembly High-Side Liquid Service Valve Water Supply Inlet Hot Gas Valve Junction Boxes Check Valves (refrigeration) Check Valve Receiver (water) Water Pump Float Switch Control Box Cleaning Valve...
  • Page 11: Remote Models (Km-1900Srj/3, Km-2200Srj3, Km-2600Srj3)

    4. Remote Models (KM-1900SRJ/3, KM-2200SRJ3, KM-2600SRJ3) Low-Side Service Valve Spray Tubes Inlet Water Valve High-Side Service Valve High-Side Liquid Service Valve Evaporator Assembly Water Supply Inlet Hot Gas Valve Check Valves (refrigeration) Thermostatic Expansion Valves Control Box High-Pressure Check Valve Switch (water) Receiver...
  • Page 12: Bin Control

    B. Bin Control 1. Single Bin Control Mechanical Bin Control Connection Overview Wire Harness Bin Control Cable Connector to Connector B Wire Harness Connector A (for upper unit) Wire Harness Connection Detail Control Board Red K4 Connector Wire Harness Connector B (for upper unit) Wire Harness Bin Control...
  • Page 13: Water/Refrigeration Circuit Diagram

    C. Water/Refrigeration Circuit Diagram 1. Air-Cooled Models (SAJ/3)
  • Page 14: Water-Cooled Models (Swj/3)

    2. Water-Cooled Models (SWJ/3)
  • Page 15: Remote Models (Srj/3)

    3. Remote Models (SRJ/3)
  • Page 16: Sequence Of Operation And Service Diagnosis

    II. Sequence of Operation and Service Diagnosis A. Sequence of Operation Flow Chart 1. Operation Flow Chart...
  • Page 17: Shutdown Flow Chart

    2. Shutdown Flow Chart...
  • Page 18: Freeze-Time Correction Chart

    3. Freeze-Time Correction Chart...
  • Page 19: Service Diagnosis

    B. Service Diagnosis WARNING • The appliance should be diagnosed and repaired only by qualified service personnel to reduce the risk of death, electric shock, serious injury, or fire. • Risk of electric shock. Control switch in "OFF" position does not de-energize all loads Use extreme caution and exercise safe electrical practices.
  • Page 20 1. Operation Diagnosis 3) Power On: Turn on the power supply, then move the control switch to the "ICE" position. A 5-sec. delay occurs. CB red "POWER OK" LED and green "BC CLOSED" LED turn on. If yellow "BC OPEN" LED is on (indicating a full bin), check BC. Move ice away from BC actuator paddle.
  • Page 21 5a) Initial Harvest Cycle – LEDs 1, 4, and 2 are on. WV and X11 relay continue. Comp, FM* (if connected to CB K1 connector pin #9), FMR, HGV, and X10 relay energize. CB monitors the warming of the evaporator via the thermistor located on the suction line.
  • Page 22 5b) Harvest Pump Time (Harvest Assist) – LEDs 1, 3, and 2 are on. When the thermistor reaches 48°F (9°C), CB reads 3.9 kΩ from the thermistor and turns harvest termination over to the harvest timer (S4 dip switch 1 & 2 and S5 dip switch 4). When WV de-energizes, LED 4 turns off, X11 relay de-energizes and LED 3 turns on.
  • Page 23 a) Freeze Cycle Diagnosis: Confirm Comp, FM* (if connected to CB K1 connector pin #9), FMR, and PM continue. Confirm that FM (if not connected to CB K1 connector pin #9) and LLV energize. Confirm WRV opens. Next, confirm HGV and X10 relay de-energize.
  • Page 24 f) Refrigerant Pressures, HM, and TXV Diagnosis: If evaporator is still not cooling, check refrigerant pressures. See "VIII.A. Specification and Performance Data." Next, check HM operation. If refrigeration pressures are above HM setpoint and HM is bypassing, replace HM. Check TXV for proper operation. Remove TXV bulb and hold it in your hand, refrigerant low-side pressure should rise, place TXV bulb in ice water, refrigerant low-side pressure should drop.
  • Page 25 pump-out is complete. The pump-out frequency control (S4 dip switch 5) is factory set, and generally no adjustment is required. However, the pump-out frequency control can be set to have a pump-out occur every 10 cycles or every cycle. For details, see "III.C.4. Pump-Out Frequency Control (S4 dip switch 5)."...
  • Page 26: Freeze-Time Correction Cycle (90 Min.)

    C. Freeze-Time Correction Cycle (90 min.) Freeze-Time Correction function is enabled when S4 Dip Switch 7 is in the "ON" position and initiates when the minimum and maximum freeze times have exceeded differential parameters. Freeze-time correction timer and count starts at the beginning of the 2nd freeze cycle after startup from power off condition.
  • Page 27 2) Freeze-Time Correction Sequence: First occurrence within 36 hr., minimum and maximum freeze times have exceeded differential parameters. CB "POWER OK" LED starts blinking. Freeze-Time Correction Cycle starts. Second occurrence within 36 hr., minimum and maximum freeze times have exceeded differential parameters.
  • Page 28: Control Board Check

    D. Control Board Check Before replacing CB that does not show a visible defect and that you suspect is bad, always conduct the following check procedure. This procedure will help you verify your diagnosis. Alarm Reset: If CB is in alarm (beeping), press the "ALARM RESET" button on CB while CB is beeping.
  • Page 29: Bin Control Check

    E. Bin Control Check 1. Bin Control Check This appliance uses a lever-actuated proximity switch to control the ice level in the storage bin. No adjustment is required. To check BC, follow the steps below. 1) Turn off the power supply. 2) Remove the front panel, then move the control switch to the "OFF"...
  • Page 30: Bin Control Cleaning

    4) Disconnect BC connector from CB K4 connector, then remove BC from the icemaker. 5) Remove the actuator paddle from the switch mount. See Fig. 2. 6) Wipe down BC with a mixture of 1 part of Hoshizaki "Scale Away" and 25 parts of warm water. Rinse the parts thoroughly with clean water.
  • Page 31: Float Switch Check And Cleaning

    F. Float Switch Check and Cleaning FS is used to determine that there is sufficient water in the water tank after the 1-min. fill cycle and after each harvest cycle. FS is also used to determine that the appropriate volume of water has been converted into ice before switching out of the freeze cycle. No adjustment is required.
  • Page 32: Float Switch Cleaning

    Be careful not to bend the retainer rod excessively when removing it. 7) Wipe down FS housing, shaft, float, and retainer rod with a mixture of 1 part Hoshizaki "Scale Away" and 25 parts warm water. Clean the inside of the rubber boot and hose with cleaning solution.
  • Page 33: Thermistor Check

    G. Thermistor Check To check thermistor resistance, follow the steps below. 1) Turn off the power supply. 2) Remove the front panel. Move the control switch to the "OFF" position. 3) Remove the control box cover. 4) Remove the thermistor from the refrigerant tubing. 5) Immerse the thermistor sensor portion in a glass containing ice and water for 2 or 3 min.
  • Page 34: Diagnostic Tables

    I. Diagnostic Tables 1. No Ice Production No Ice Production - Possible Cause 1. Power Supply a) Off, blown fuse, or tripped breaker. b) Not within specifications. 2. Main Transformer a) Voltage tap switch not set to proper voltage. (if applicable) b) Coil winding open or shorted.
  • Page 35 No Ice Production - Possible Cause 16 Thermostatic Expansion Valve a) Bulb loose. b) Operating erratically. 17. Liquid Line Valve a) Closed in freeze cycle. b) Open in harvest cycle. 18. Fan Motor a) Motor winding open. b) Bearing worn out or locked rotor. c) Defective capacitor.
  • Page 36 3. Freeze-Up Defrost and clean the icemaker prior to diagnosing freeze-up. Fill out a freeze-up checklist. See "II.J. Freeze Up Check List," the Hoshizaki America Technician's Pocket Guide, or contact your local distributor for a copy of the freeze-up checklist.
  • Page 37 Freeze-Up - Possible Cause 8. Control Board a) Harvest timer (S4 dip switch 1 & 2) set too short. See "II.D. Control Board b) Harvest pump time (harvest assist) (S4 dip switch 7) not in factory Check" and "III.D. Settings and default position.
  • Page 38: Freeze-Up Check List

    J. Freeze-Up Check List Freeze-Up Check List Please Complete When Diagnosing a Freeze-Up, Refrigerant Leak, or Low Charge Technical Support Fax #: 770-487-3360 Make Copies And Use As Needed Model #___________________________ Serial # ____________________Install Date____________Freeze-Up Date___________ List model and manufacture of bin or dispenser__________________________. Date appliance was last cleaned:__________.
  • Page 39: Controls And Adjustments

    III. Controls and Adjustments • A Hoshizaki exclusive control board is employed in KM and KMH series appliances. • All models are pretested and factory adjusted. • For a control board check procedure, see "II.D. Control Board Check." NOTICE • Fragile, handle very carefully.
  • Page 40: Control Board Layout

    A. Control Board Layout "J" Control Board • Bin Control Switch Closed LED (green) • "OUTPUT TEST" Button • S4 Dip Switch • "ALARM RESET" Button (used to test relays on control board) • K3 (white) Connector • Bin Control Switch Open LED (yellow) Thermistor (harvest control and...
  • Page 41: Led Lights And Audible Alarm Safeties

    B. LED Lights and Audible Alarm Safeties Beep occurs and red "POWER OK" LED turns on when control switch is moved to "ICE" position. Sequence Green LEDs 1 through 4 turn on and sequence from initial startup as listed in the table below.
  • Page 42: Settings And Adjustments

    Dip switches are factory set. Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact your Hoshizaki Service Center. 1. Default Dip Switch Settings The dip switches are factory-adjusted to the following positions for both the 2A7664 -01...
  • Page 43: Harvest Time (S4 Dip Switch 1 & 2)

    2. Harvest Time (S4 dip switch 1 & 2) The harvest timer starts counting when the thermistor reaches 48°F (9°C) at the evaporator outlet and the control board reads 3.9 kΩ from the thermistor. The harvest timer is factory set, and generally no adjustment is required. However, a setting longer than the factory setting may be advised in cases where the drain provided at harvest needs to be prolonged for extra cleaning.
  • Page 44: Pump-Out Frequency Control (S4 Dip Switch 5)

    4. Pump-Out Frequency Control (S4 dip switch 5) The pump-out frequency control is factory set to drain the water tank every 10 cycles. Generally no adjustment is required. However, where water quality is bad and the icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The pump-out frequency control can be set to have a pump-out occur every cycle, or every 10 cycles.
  • Page 45: Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (S4 Dip Switch 7)

    6. Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (S4 dip switch 7) NOTICE Factory set for proper operation. Do not adjust. Adjustment outside of the factory default setting may result in damage to the appliance. a) Harvest Pump Time (Harvest Assist) Depending on S4 dip switch 7 setting, the pump motor either stays off or is energized during the last seconds of the harvest cycle.
  • Page 46: Freeze Timer (S4 Dip Switch 9 & 10)

    In this case, see "II.G.3. Low Ice Production" for possible solutions. The freeze timer is factory set and no adjustment is required. Before changing this setting, contact Hoshizaki Technical Support at 1-800-233-1940 for recommendations.
  • Page 47 11. Minimum Harvest Time (S5 dip switch 4) NOTICE Factory set for proper operation. Do not adjust. Adjustment outside the factory default setting may result in damage to the appliance. S5 Dip Switch Setting Minimum Harvest Timer No. 4 120 sec. 70 sec.
  • Page 48: Refrigeration Circuit And Component Service Information

    IV. Refrigeration Circuit and Component Service Information WARNING • This appliance should be diagnosed and repaired only by qualified service personnel to reduce the risk of death, electric shock, serious injury, or fire. • Move the control switch to the "OFF" position and turn off the power supply. Place the disconnect in the "OFF"...
  • Page 49 2. Brazing WARNING • R-404A itself is not flammable at atmospheric pressure and temperatures up to 176°F (80°C). • R-404A itself is not explosive or poisonous. However, when exposed to high temperatures (open flames), R-404A can be decomposed to form hydrofluoric acid and carbonyl fluoride both of which are hazardous.
  • Page 50 Remember to loosen the connection and purge the air from the hose. For the required refrigerant charge, see the rating label inside the icemaker. Hoshizaki recommends only virgin refrigerant or reclaimed refrigerant which meets ARI Standard 700 (latest edition) be used.
  • Page 51: Component Service Information

    • The thermistor should be at the 12 o'clock position on the tube. • Smoothly fill the recessed area of the thermistor holder with high thermal conductive type sealant. Hoshizaki America part number 4A0683-01 (Silicone Heat Sink Compound 10-8108 manufactured by GC Electronics), KE-4560 RTV (manufactured by ShinEtsu Silicones), or equivalent are recommended.
  • Page 52: Water Regulating Valve Adjustment (Water-Cooled Models)

    C. Water Regulating Valve Adjustment (water-cooled models) The water regulating valve is factory set, and generally no adjustment is required. However, when necessary, adjust the water regulator using the following procedure. 1) Prepare a thermometer to check the condenser drain temperature. Attach a pressure gauge to the high-side line of the system.
  • Page 53: Maintenance

    V. Maintenance The maintenance schedule below is a guideline. More frequent maintenance may be required depending on water quality, the appliance's environment, and local sanitation regulations WARNING • Only qualified service technicians should service the appliance. • To reduce the risk of electric shock, do not touch the control switch or service switch with damp hands •...
  • Page 54: Preparing The Icemaker For Periods Of Non-Use

    VI. Preparing the Icemaker for Periods of Non-Use NOTICE • When storing the appliance for an extended time or in sub-freezing temperatures, follow the instructions below to prevent damage. • To prevent damage to the water pump, do not operate the appliance with the control switch in the "WASH"...
  • Page 55 3. On water-cooled model, remove the water from the water-cooled condenser: 1) Make sure the power supply is off, then remove the front, top, and right side panels. 2) Close the condenser water supply line shut-off valve. If connected to a closed loop system, also close the condenser return line shut-off valve.
  • Page 56: Disposal

    VII. Disposal The appliance contains refrigerant and must be disposed of in accordance with applicable national, state, and local codes and regulations. Refrigerant must be recovered by properly certified service personnel.
  • Page 57: Technical Information

    VIII. Technical Information We reserve the right to make changes in specifications and design without prior notice. A. Specification and Performance Data Pressure data is recorded at 5 min. into freezing cycle. The data not in bold should be used for reference only. 1.
  • Page 58: Km-1301Saj3

    2. KM-1301SAJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 9.5 A MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2220(3.95) 2080(3.50) WATER gal./24HR (gal./100 lbs.) 211(15.6) 598(41.9) ICE PRODUCTION PER CYCLE 29.9 lbs.
  • Page 59: Km-1301Swj

    3. KM-1301SWJ Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 AMPERAGE 8.2 A MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1930(3.76) 1900(3.66) WATER gal./24HR (gal./100 lbs.) 258(21.0) 479(38.4) WATER COOLED CONDENSER 1095(89) 682(55) gal./24HR (gal./100 lbs.)
  • Page 60: Km-1301Swj3

    4. KM-1301SWJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 6.1 A MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 1830 (3.25) 1850 (3.27) WATER gal./24HR (gal./100 lbs.) 217 (16.0) 464 (34.1) WATER COOLED CONDENSER 1287 (95)
  • Page 61: Km-1301Srj With Urc-14F

    5. KM-1301SRJ with URC-14F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 AMPERAGE 13.5 A MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2250(4.28) 2070(3.55) WATER gal./24HR (gal./100 lbs.) 176(14.0) 511(36.5) ICE PRODUCTION PER CYCLE 29.4 lbs.
  • Page 62: Km-1301Srj3 With Urc-14F

    6. KM-1301SRJ3 with URC-14F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 10.7 A MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2120 (3.83) 2020 (3.38) WATER gal./24HR (gal./100 lbs.) 186 (14.0) 466 (32.6) ICE PRODUCTION PER CYCLE...
  • Page 63: Km-1601Saj

    7. KM-1601SAJ Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V) AMPERAGE 15.9 MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2530 (4.24) 2320 (3.68) WATER gal./24HR (gal./100 lbs.) 301 (21.0) 681 (45.0)
  • Page 64: Km-1601Saj3

    8. KM-1601SAJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 12.9 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2590 (4.40) 2320 (3.68) WATER gal./24HR (gal./100 lbs.)
  • Page 65: Km-1601Swj

    9. KM-1601SWJ Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V) AMPERAGE 13.6 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.)
  • Page 66: Km-1601Swj3

    10. KM-1601SWJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 8.8 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2300 (3.32) 2290 (3.29) WATER gal./24HR (gal./100 lbs.)
  • Page 67: Km-1601Srj With Urc-22F

    11. KM-1601SRJ with URC-22F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 AMPERAGE 15.9 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2640 (3.96) 2510 (3.68) WATER gal./24HR (gal./100 lbs.)
  • Page 68: Km-1601Srj3 With Urc-22F

    12. KM-1601SRJ3 with URC-22F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2760 (4.14) 2760 (4.05) WATER gal./24HR (gal./100 lbs.)
  • Page 69: Km-1900Saj

    13. KM-1900SAJ Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V) AMPERAGE 14.5 MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2720 (3.90) 2500 (3.20) WATER gal./24HR (gal./100 lbs.) 318 (19.0) 420 (22.4)
  • Page 70: Km-1900Saj3

    14. KM-1900SAJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 8.9 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2720 (3.90) 2420 (3.12) WATER gal./24HR (gal./100 lbs.)
  • Page 71: Km-1900Swj

    15. KM-1900SWJ Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V) AMPERAGE 15.8 A MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2500 (3.20) 2440 (3.11) WATER gal./24HR (gal./100 lbs.) 394 (21.0) 421 (22.4)
  • Page 72: Km-1900Swj3

    16. KM-1900SWJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2500 (3.20) 2370 (3.03) WATER gal./24HR (gal./100 lbs.) 394 (21.0) 368 (19.6) WATER COOLED CONDENSER 1594 (85) 921 (49)
  • Page 73: Km-1900Srj With Urc-22F

    17. KM-1900SRJ with URC-22F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/1 AMPERAGE 15.9 A MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2760 (3.90) 2480 (3.08) WATER gal./24HR (gal./100 lbs.) 323 (19.0) 528 (27.3) ICE PRODUCTION PER CYCLE...
  • Page 74: Km-1900Srj3 With Urc-22F

    18. KM-1900SRJ3 with URC-22F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 13.5 MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2760 (3.90) 2460 (3.06) WATER gal./24HR (gal./100 lbs.) 323 (19.0) 564 (29.2) ICE PRODUCTION PER CYCLE...
  • Page 75: Km-2200Swj3

    19. KM-2200SWJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 2850 (3.11) 2830 (3.06) WATER gal./24HR (gal./100 lbs.)
  • Page 76: Km-2200Srj3 With Urc-22F

    20. KM-2200SRJ3 with URC-22F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 15.9 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 20 A MAXIMUM FUSE SIZE 20 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 3240 (3.75) 2970 (3.23) WATER gal./24HR (gal./100 lbs.)
  • Page 77: Km-2600Swj3

    21. KM-2600SWJ3 Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 3720 (3.60) 3630 (3.51) WATER gal./24HR (gal./100 lbs.)
  • Page 78: Km-2600Srj3 With Urc-26F

    22. KM-2600SRJ3 with URC-26F Specification Sheet AC SUPPLY VOLTAGE 208-230/60/3 AMPERAGE 20.6 A ( 5 Min. Freeze AT 104°F / WT 80°F) MINIMUM CIRCUIT AMPACITY 30 A MAXIMUM FUSE SIZE 30 A ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F ELECTRIC W (kWH/100 lbs.) 3880 (3.61) 3330 (3.05) WATER gal./24HR (gal./100 lbs.)
  • Page 79: Wiring Diagrams

    B. Wiring Diagrams 1. Single Phase Models a) KM-1301S_J...
  • Page 80: B) Km-1601S_J

    b) KM-1601S_J...
  • Page 81: C) Km-1900S_J

    c) KM-1900S_J...
  • Page 82: Three Phase Models

    2. Three Phase Models a) KM-1301S_J3...
  • Page 83: B) Km-1601S_J3

    b) KM-1601S_J3...
  • Page 84: C) Km-1900_2200_2600S_J3

    c) KM-1900_2200_2600S_J3...

Table of Contents