Ice Machine
The ice maker must be cleaned & sanitized at least once a year.
Cleaning Prep:
1
Remove the Front Panel, move the control switch to OFF.
After 3 min., move the switch to ICE, then replace the panel.
2
After 3 min., remove the Front Panel, move the switch to OFF.
3
Remove all ice from the ice storage bin and/or dispenser
WARNING! IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the leftover ice.
Cleaning:
Front View of Ice Maker with Front Panel removed
4
Remove the Front Insulation Panel, remove the Drain Plug. After the water tank
has drained, replace Drain Plug. Replace the Front Insulation Panel.
NOTICE! DO NOT cross thread the drain plug.
5
Refill water tank by moving the control switch to ICE,
replace the Front Panel. After 3 minutes, remove the
Front Panel, then move the control switch to OFF.
6
Remove the Front Insulation Panel. Pour Hoshizaki
Scale Away into the water tank (see Table).
Replace the Front Insulation Panel. Turn the cleaning valve left until completely
vertical (open).
NOTICE! AVOID EXCESSIVE FOAMING, wait
1 minute before next step.
#51002 | 7.21.2016
Cleaning & Sanitizing
 continued on the back...
Tech Support: 1.800.233.1940
3
min
.
3
min.
3
min.
OPEN
KM-1301SAH/3, SWH/3, SRH/3
KM-1601SAH/3, SWH/3, SRH/3
KM-1900SAH/3, SWH/3, SRH/3
KM-2100SWH3, SRH3
KM-2500SWH3, SRH3
WARNING!
DO NOT leave icemaker
unattended when panels are off
AMMONIA
Cleaners
Sanitizing:
• Fill the water tank
CLOSE
the cleaning valve
• Move control switch to ICE,
replace the front panel
• After 3 minutes, remove the
front panel
• Move control switch to OFF
• Remove the front insulation
panel
• Pour chlorine bleach* into the
water tank (see below)
KM-1601 and smaller
3.75 fl. oz (110 ml)
KM-1900 and larger
5 fl. oz (148 ml)
• Replace the front insulation
panel
OPEN
the cleaning valve
* Use bleach without additives.
Additives cause excessive foaming, and
reduces effectiveness of the cleaning.
• Wait 1 minute to avoid
excessive foaming
• Move control switch to WASH,
replace the front panel
• After 45 minutes, remove
the front panel
• Move control switch to OFF
14
15
16
17
Page 1

Advertisement

loading

Summary of Contents for Hoshizaki KM-1301SRH/3

  • Page 1 Front Panel, then move the control switch to OFF. • Move control switch to WASH, Remove the Front Insulation Panel. Pour Hoshizaki replace the front panel Scale Away into the water tank (see Table). Replace the Front Insulation Panel. Turn the cleaning valve left until completely •...
  • Page 2 Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep  sanitizing continued… Move the control switch to WASH, replace Front Panel. After 30 minutes, remove Front Panel, then move the • Remove the front min. control switch to OFF.