AVE VSI-Pro Max Operation Manual page 45

Pos / cash register interface
Hide thumbs Also See for VSI-Pro Max:
Table of Contents

Advertisement

5. PROGRAMMING
NOTE: The default RegCom/VNET address of the internal Cash Register port of the VSI-Pro Max as a Master is N/A.
Therefore you must select what address you require to be assigned to the POS or Cash Register data so the DVR will
assign the register data to the proper camera. This address must be unique to all the other addresses of slaves on the
Network just like all the slaves must have a unique address.
Related Settings
"ADDRESS" selects the RegCom address of the internal Cash Register port N/A, 1-16
"PROTOCOL" which the choices are REGCOM 9.6K, REGCOM 57.6K or VNET
"TX PROTOCOL" which the choices will be MVDR, DALLMEIER, VSI-ADD, VNET, NORBAIN VISTA
"BAUD RATE" 1200- 115.2K
SLAVE
This setting confirgures the Network RJ45 port to be a Slave which is formerly called Regcom or Vnetworker. The Slave
uses RS-485 bi-directional communication to the Master unit.
Related Settings
"ADDRESS" choices are N/A, 1-16
"PROTOCOL" which the choices are REGCOM 9.6K, REGCOM 57.6K or VNET
"BAUD RATE" 1200 - 115.2K
If the Type is set to OFF then no data is sent out the Network Port either via RS-232 or RS-485.
ADDRESS
Choices: N/A, 1-16
This selects the address or camera number when configured as a slave device. The selections are 1-16 so that the
POS/Cash Register is assigned a unique number up to a maximum of 16 to send the data over the RS-485 network
back to a Master unit or a Hydra device which then sends all the data to the DVR or PC via the VSI-ADD for recording.
PROTOCOL
Choices: REGCOM 9.6K, REGCOM 57.6K or VNET
This setting selects the protocol of the RS-485 Network. There are two protocols to be compatible with two different
devices and functions. The REGCOM can be selected for compatibility with the RegCom networking device. The
RegCom device can be set for either 9600 or 57600 baud rate to match the installed device settings. However when not
using the RegCom device and using only VSI-Pro Max then any baud rate can be set. The RegCom Protocol only has
the ability to receive register data only to be backward compatible with RegCom device connected with a VSI-Pro.
The VNET can be configured for compatibility with the Vnetworker or Networker devices. A baud rate of 19200 can be
only used for these external devices. However when used with a VSI-Pro Max device and no external Vnetworker or
Networker devices are used then any baud rate can be used. The Vnetworker protocol has the ability to receive register
data, Program remote VSI-Pro Max devices, and Receive remote Alarming and Time/Date information.
BAUD RATE
Choices: 1200 - 115200 baud rate
This sets the communication speed for the Network port in all configurations. Care must be given to selecting the proper
baud rate for the Type of operation you wish and configuration you set for the VSI-Pro Max.
EXIT
Press the "Up" or "Down" button to move the cursor to "EXIT" and press "Set" to return to the previous menu.
VSI-Pro Max POS / Cash Register Interface
45