Installing the RPS enablement option
Installing the RPS enablement option
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel .
6. If installed, remove all media drives .
7. Disconnect all non-hot-plug power supply cables .
8. Remove the non-hot-plug power supply:
a. Remove the power supply screws (callout 1).
b. Press and hold the release latch (callout 2), and then remove the power supply (callout 3).
Installing the RPS enablement option
96