SPECIFICATIONS
6
8
9
Model ¹,
,
,
Voltage ¹, ³
Capacity (BTU/h)
10
Amps
10
Watts
EER
Unit without Electric Heater
4
10
Min. Circuit Amps ²,
,
High
CFM (Cool/Wet Coil)
Low
High
CFM (Dry Coil)
Low
Ventilated Air, CFM (Fan Only)*
Dehumidification (Pints/Hr.)
Net Weight (lbs.)
Ship Weight (lbs.)
Notes:
¹
All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
²
Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
³
Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.
4
Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses
(included and factory-installed on all Amana® brand 265-volt chassis). See heater perform
5
Heating capacity and efficiency based on unit operation without condensate pump.
6
Specify two-digit heater kW size to complete model number.
7
R-410A refrigerant used in all systems. R-134A used in Kit Fresh Air.
8
All units meet or exceed ASHRAE 90.1 standards.
9
All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
10
Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
EER -
Energy Efficiency Ratio per The Air-Conditioning, Heating, and
Refrigeration Institute (AHRI) Test Procedures and Canadian
Standards Association (CSA) Test Procedures.
COP - Coefficient of Performance per AHRI Test Procedures
PTH
PTH
073G**
093G**
230 / 208
230 / 208
7,100 / 7,000
9,000 / 9,000
11,600 / 11,400 14,200 / 14,400
3.3 / 3.3
4.1 / 4.1
560 / 535
705 / 685
12.0 / 12.4
11.9 / 12.0
4.0
5.0
330
330
245
245
360
360
270
270
40*
65*
1.7
2.2
111
112
131
127
PTH
PTH
123G**
153G**
230/208
230 / 208
6.1 / 6.1
7.0 / 7.0
970 / 960
1,430 / 1,410
11.0 / 11.1
9.9 / 9.9
7.4
8.6
330
390
245
340
360
410
270
370
65*
65*
2.2
4.4
123
126
141
143
PTH G SERIES
PTH
PTH
074G**
094G**
265
265
7,600
9,100
3
3.6
645
755
11.7
12
3.6
4.4
330
330
245
245
360
360
270
270
65*
65*
2.2
2.2
108
112
123
127
PTH
PTH
124G**
154G**
265
265
12,000
14,600
4.9
6.1
1090
1,505
11
9.7
6.0
7.4
390
390
340
340
410
410
370
370
65*
65*
4.4
4.4
124
125
142
142
8