Maytag Amana PMH Series Service And Troubleshooting page 5

Package terminal air conditioner/heatpump
Table of Contents

Advertisement

SPECIFICATIONS
1, 7, 9, 10
Model
Voltage ¹, ³
Capacity (BTU/h)
11
Amps
11
Watts
EER
Unit without Electric Heater
2, 5, 11
Min. Circuit Amps
High
CFM (Cool/Wet Coil)
Low
High
CFM (Dry Coil)
Low
Ventilated Air, CFM (Fan Only)**
Dehumidification (Pints/Hr.)
Net Weight (lbs.)
Ship Weight (lbs.)
* Information in this manual applies only to the BA revision of 0902G*** model.
** Actual vent CFM performance will vary due to application and installation conditions.
Notes:
¹
All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
²
Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
3
Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.
4
Minimum voltage on 115-volt models is 104 volts; maximum is 127 volts.
5
Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be cartridge-style time-delay fuses
(included and factory-installed on all Amana® brand 265-volt chassis). See heater perform
6
Heating capacity and efficiency based on unit operation without condensate pump.
7
Specify two-digit heater kW size to complete model number.
8
R-410A refrigerant used in all systems.
9
All units meet or exceed ASHRAE 90.1 standards.
10
All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
11
Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation refers to compressor only.
EER -
Energy Efficiency Ratio per The Air-Conditioning, Heating, and
Refrigeration Institute (AHRI) Test Procedures and Canadian
Standards Association (CSA) Test Procedures.
COP - Coefficient of Performance per AHRI Test Procedures
PTC
PTC
PTC
073G**
074G**
092G***BA*
230/208
265
115
7,000 / 7,000
7,000
9,000
3.1 / 3.1
2.7
580 / 560
585
795
12.0 / 12.5
11.9
11.3
3.7
3.2
330
340
290
245
245
264
360
370
310
270
270
282
40*
65*
65**
1.7
1.7
106
103
102
115
115
117
PTC
PTC
093G***
094G***
230 / 208
265
9,200 / 9,000
9,100
8.3
4.1 / 4.1
3.6
790 / 765
805
11.6 / 11.7
11.3
8.3
4.9
4.4
290
290
264
264
310
310
282
282
65**
65**
2.2
2.2
2.2
102
102
117
117
PTC G SERIES
PTC
PTC
123G**
124G***
153G***
230/208
265
230 / 208
11,900 /11,700
12,200
14,800 / 14,500
6.0 / 6.0
4.8
7.0 / 7.0
1,080 / 1,060
1,170
1,480 / 1,450
11.0 / 11.0
10.4
10.0 / 10.0
7.3
5.8
340
340
245
245
370
370
270
20
40*
40**
1.7
1.7
108
108
125
125
PTC
PTC
154G***
265
14,800
6.1
1,480
10.0
8.5
7.4
340
340
314
314
360
360
332
332
65**
65**
4.4
4.4
113
113
130
130
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents