Omron FHV7H-C004-H19-MC Hardware Setup Manual page 141

Vision sensor
Table of Contents

Advertisement

l RS-232C Connection (Cable Length Up to 10 m)
FH-MT12
Analog RGB
A video signal cable and an operation signal cable are required to connect the Touch Panel Moni-
tor.
Signal
Video signal
Touch panel operation
signal
Wiring
The power terminal block for the Touch Panel Monitor is located on the back of it.
Connect a power supply of 24 VDC there.
24 VDC
Power supply
24 VDC
Indication on the
power terminal
block
+
-
• Wire the power supply wires as short as possible. (Max.2 m)
• If UL's certification is required, use a UL class II power supply.
• Use the cables and crimping terminals with the specified dimensions.
Do not directly connect an electric wire that is simply twisted to the terminal block.
FH Series Vision System Hardware Setup Manual (Z366-E1)
Touch panel cable(RS-232C):
XW2Z-
D-Sub
Monitor cable: FH-VMDA
RS-232C
DVI-Analog Conversion Cable
USB Cable
RS-232C Cable
M4
Recommended model
by OMRON:
S8VS-03024
Name
DC input terminal
Connect to the DC output terminal (+V) of 24 VDC power.
(+V)
DC input terminal (-
Connect to the DC output terminal (-V) of 24 VDC power.
V)
FG (Functional
Connect to the earth.
grounding terminal)
Functional grounding is done to protect device and system func-
tions, including prevention of noise from external sources, or pre-
vention of noise from devices or equipment that could have harm-
ful effects on other devices or equipment
PP-1
DVI-A
RS-232C
DVI-I
Sensor Controller
Cable
OK
OK
OK
Function
3 Configuration
2 m
5 m
10 m
OK
OK
OK
-
OK
OK
3
3-83

Advertisement

Table of Contents
loading

Table of Contents