6.4.3.1

Device status (master only)

You can view the current status of the slaves on this page. These are mainly static values
that the slave only transmits to the master during the login process.
You can find a general description of the tables in Status tables (Page 102).
The following columns are always displayed:
● "Connected on": Time at which the connection to the slave was set up.
● "PN name": PROFINET name of the slave.
● "IP address": IP address of the slave.
● "FW version": The PLB FW version of the slave.
You can display the current position of the slaves via the "Position info" switch. However, this
value is only available if the current position of the PLB slave is transmitted via the
PROFINET IO interface.
● "Position": Shows the current position of the slave (only if this is transmitted via PN-IO
(Page 64)).
By default, the active "Device errors" of the slaves are displayed as well. You can find a
detailed description of the errors in Error status and warnings of the device (Page 81).
● "Rescue Mode": A slave restarted with the Rescue firmware after a fatal error.
● "Log backup": A slave has created a backup of the log files after restart in Rescue mode
to determine the cause of the error.
● "Core Dump": The modem firmware of a slave has restarted after a fatal error and log
files were created to determine the cause of the error.
The following columns are displayed in the table with the "Hardware information" switch:
● "Modem MAC": The MAC address of the PLB modem module of the slave is listed here.
● "Basic MAC": The MAC address of the PLB basic module of the slave is listed here.
● "HW Modem": The hardware version of the PLB modem module of the slave is listed
here.
● "HW Basic": The hardware version of the PLB basic module of the slave is listed here.
The configuration of the signal gain (Page 100) of the individual slaves can be viewed using
the "Signal configuration" switch:
● "TX": Configured static transmit gain of the powerline signal on the slave.
● "RX": Configured static receive gain of the powerline signal on the slave.
● "RX Limit": The configured limit value of the receive gain on the slave.
Power Line Booster
Operating Instructions, 11/2019, A5E36203125A-AG
System configuration and system status (web interface)
6.4 Powerline
103