Device description
2.2 PLB Basic module
2.2.2

DIP switches

Figure 2-5
No settings are necessary (factory state) when you use the Power Line Booster as slave. To
use the PLB as master, however, you must set the DIP switch "M/S" accordingly.
In some special cases, you may have to make additional settings.
The possible settings are listed in the "Operator controls" table.
The switches are located below the PLB EM (Empty Module).
NOTICE
Use the DIP switches for configuration only in the de-energized state.
Table 2- 1
Operator controls
Operator control
Labeling
DIP switch
M/S
Master/Slave
DIP switch
CH 0
Channel
CH 1
14
DIP switches
State
Off (factory state)
On
Channel
1 (delivery state)
2
3
4
Function
PLB slave operation
PLB master operation
CH 1 CH 0
Setting of 4 different chan-
0
0
nels.
0
1
1
0
1
1
Operating Instructions, 11/2019, A5E36203125A-AG