Heat demand factor

Menu → Installer → Startup
Setting for selecting the heat demand, which the installer can use to adjust the charge intensity and general domestic heating performance to suit the
structural features on site and the user's individual heat demand. The parameter should be set so that it reflects the user's desired living comfort at
heat level 3.0. The use of insulation will reduce the heat demand factor; if a higher room set temperature is always desired then the heat demand
factor increases.
Factory setting: 100% (normal demand according to characteristic curve E1/E2), adjustment range: 30% to 200%

Sensor type

Menu → Installer → Startup
Setting for selecting the type of sensor for the outdoor temperature sensor. As a rough guide, three temperatures are additionally shown (20°C, 0°C
and -15°C), as well as the corresponding resistance values for the temperatures (for example, 2k4 for short denoting 2.4 kΩ for a temperature of
20°C with the Dimplex standard sensor DIN).
Factory setting: Dimplex standard sensor DIN, adjustment range: for the available sensor types please see Technical device information, p. 4.
Control model for charging (only shown with the classic charging model)
Menu → Installer → Startup
Setting for selecting the charging model for the classic method according to DIN EN 50350, forward control (with and without timing) and backward
control.
Factory setting: backward, adjustment range: forward without timing | forward with timing | backward
Runtime (only shown with the classic charging model)
Menu → Installer → Startup (only for classic applications)
Setting for selecting the runtime in hours once the main release starts, for starting up the classic charging models faster after a prolonged power cut.
Enter the number of hours that have passed since the night-time release was last started here. Example: setting in the morning at 11:00 upon
startup, night-time release at 22:00 → 13 hours).
Factory setting: 0 h, adjustment range: 0 h to 23 h