Terminal Assignment - Dimplex ZWU 06E Installation And Operating Instructions Manual

Central control unit with timer function
Table of Contents

Advertisement

Terminal assignment for the ZWU 06E central control unit
* Reserved terminals must not be used as supporting terminals.
** Caution: when commissioning the device, it is essential to set the correct type for the connected sensor!
10
Terminal Function
ZX
DC control signal output (+)
Z0
DC control signal output (-)
ZY
DC control signal output (day/night) for underfloor charge controller
(reserved*)
Ground
C
(reserved*)
FS
Frost protection
WF
External sensor input**
L
Supply voltage
N
Supply voltage
Z2~
Control signal output to the storage heaters; internally connected with N
Z1~
Control signal output to the storage heaters; clocked control cable (230V~)
with duty cycle signal
TGN230 (reserved*)
LF
Signal input: charge release from network operator
LX
Multi-function input; can be assigned various functions via the software (see start signal for
drive (LL) and blocking signal for high tariff (HT))
LZ
Signal input: additional release from network operator
SH
Switching output for controlling the heating contactor
L
Supply voltage
N
Supply voltage