Citizen COMPACT CT-S310II Service Manual page 14

Hide thumbs Also See for COMPACT CT-S310II:
Table of Contents

Advertisement

CT-S310II Series Service Manual
Remove "SCREW, PH (SW), M4.0  6" from "FRAME, BOTTOM-03" and disconnect the frame ground
cable. Remove three "SCREW, TP (ST), M3.0  5" that fasten "FRAME, BOTTOM-03" and "PWB
(MAIN_PCB30)".
SCREW, PH (SW), M4.0  6
Frame ground cable
POWER SW
Insert the power switch into the notch
at "FRAME, BOTTOM-03".
6.
Disassembling "SA, CUTTER UNIT"
Pull "LEVER R & L, CUTTER RELEASE" toward you to raise "SA, CUTTER UNIT" and remove "SA,
CUTTER UNIT" from "FRAME, MAIN-03". Remove the cable from the connector.
SA, CUTTER UNIT
Connector
Hooks
<Precaution at disassembly / reassembly>
When assembling or disassembling "PWB (MAIN_PCB30)", be sure
to avoid contacting any part of "FRAME, BOTTOM-03" (especially
capacitors).
Be careful not to deform the power switch when inserting it into the
notch at "FRAME, BOTTOM-03".
LEVER L, CUTTER RELEASE
CABLE
- 12 -
PWB (MAIN_PCB30)
SCREW, TP (ST), M3.0  5
Be sure to avoid contacting the
capacitors.
<Precaution at disassembly /
reassembly>
When disconnecting the connector,
do not pull the cable by force.
When reassembling, hang the cable
to the hook. Be careful not to catch
the cable.

Advertisement

Table of Contents
loading

Table of Contents