Toshiba E-STUDIO 2020AC Frequently Asked Questions Manual page 75

Hide thumbs Also See for E-STUDIO 2020AC:
Table of Contents

Advertisement

10.QUESTIONS FOR ERROR CODES
Error code
2D30
Failure to create directory
2D31, 2D33
Failure to create file
2D32
Failure to delete file
2D40
Failed to convert image file format
2D43
Encryption error. Failure to create a file Perform the job again. If the error still persists, turn the
2D44
Creating a file was not allowed
2D50
Executed [Scan to File] without logging
in being done by a user or department
in the setting which requires
authentication
2D62
Failure to connect to the network
2D63
Invalid network path specified
2D64
Failure to log into the file server
2D66
Failed to process your job. Insufficient
Storage space.
2D67
FTP service is not available
Description
Corrective action
Check that the access privilege to the storage directory is
writable and also that the disk in the directory has enough
space. Then reattempt the job in error.
If more than one job is performed simultaneously, the
error may occur because the storage device temporarily
runs out of space. I Wait for a while and reattempt the
operation. If the error still persists, turn the power OFF and
then back ON. Then reattempt the job in operation.
Check that the access privilege to the storage directory is
writable and also that the disk in the directory has enough
space. Then reattempt the job in error.
If more than one job is performed simultaneously, the
error may occur because the storage device temporarily
runs out of space. I Wait for a while and reattempt the
operation. If the error still persists, turn the power OFF and
then back ON. Then reattempt the job in operation.
Check that the access privilege to the storage directory is
writable. Then reattempt the job in error. If the error still
persists, turn the power OFF and then back ON. Then
reattempt the job in operation.
If this error has occurred while converting the file to a
highly compressed PDF format, reattempt the operation. If
the error still persists, use the normal PDF format. When
this error has occurred while converting the file to other
than a highly compressed PDF format, turn the power OFF
and then back ON. Then reattempt the operation. If the
error still persists, contact your service representative.
power OFF and then back ON. Then reattempt the
operation.
Creating an unencrypted file was not allowed. Configure
the encryption settings and reattempt the job in error. To
create an unencrypted file, ask your administrator.
Have a user or a department log in and reattempt [Scan to
File].
Make sure that the network path is correct, and retry the
scan. If the error still occurs, ask your administrator to
confirm whether the IP address or path of the server is
correct. Also make sure that the server is operating
properly.
Make sure you specify correct network folder and retry the
scan. In case of Meta scan, confirm the destination path.
Make sure you specify correct user name and password to
logon the file server and retry the scan.
Reduce the number of pages of the job in error and
reattempt the operation. In addition, check whether the
server or local storage device has sufficient space in its
storage capacity.
Ask your administrator whether the FTP service is
configured correctly.
Questions for Error Codes 75