Agilent Technologies E1439 User Manual page 131

Vxi 70 mhz if adc with filters and memory
Table of Contents

Advertisement

AGE1439_SIG_BW_MAX
minimum.
AGE1439_SIG_BW_MIN
maximum.
sigBwPtr
points to the current value of the sigBw parameter.
Caution
Selecting AGE1439_DECIMATE_ON when sigBw=0 results in aliasing (garbage data) due
to upper limit of the sampling frequency and, therefore, causes the SETUP_ERROR bit to
be set.
Selecting AGE1439_DECIMATE_SHIFT for non-zoomed data is not a useful configuration.
Comments
To ensure full alias-free operation the analog anti-alias filter (set by the age1439_input_alias_
filter function) should be ON unless the application inherently bandlimits the input signal to less
than fs/2. The analog anti-alias filter has a fixed bandwidth and thus is fully effective only when fs
≥ 100 MHz. If a slower external ADC clock is used, an additional analog filter of the appropriate
bandwidth may be required for full alias protection.
The decimation process used to reduce the output sample rate is driven from a "decimation
counter" which keeps track of which samples to save and which ones to discard for each of the
octave bandwidth reduction filter stages. In multi-module systems where synchronous sampling is
required, the decimation counters in all the modules must be synchronous with each other. This
condition can be forced by using the age1439_filter_sync function.
The following table lists parameter combinations (see also
which result in invalid measurement conditions:
All other combinations are valid.
Example
Here are some bandwidth and sample rate results using the "k" calculation for bandwidth:
fs = 100 MHz default internal ADC clock (all data in MHz)
k=.62 for 110 dB bandwidth
sets sigBw to the maximum value and the filter bandwidth to the
sets sigBw to the minimum value and filter bandwidth to the
Invalid parameter combinations
resolution
(bits)
12 or 24
12 or 24
12 or 24
24
24
12 or 24
Agilent E1439 Programmer's Reference
"age1439_data_setup" on page
dataType
decimate
REAL or COMPLEX
OFF or SHIFT
REAL or COMPLEX
ON or SHIFT
COMPLEX
any
REAL or COMPLEX
OFF
REAL or COMPLEX
any
COMPLEX
SHIFT
Functions listed alphabetically
90)
sigBw
1
0
0
2
0 or 1
any
121

Advertisement

Table of Contents
loading

Table of Contents