Agilent Technologies E1439 User Manual page 102

Vxi 70 mhz if adc with filters and memory
Table of Contents

Advertisement

Agilent E1439 Programmer's Reference
Functions listed alphabetically
when dataType is set to AGE1439_REAL and there is a non-zero center frequency the data scale
value is doubled for consistent spectrum measurements
dataTypePtr
points to the current value of the dataType parameter.
mode
selects whether the Agilent E1439's data collection operates in block mode or continuous mode.
AGE1439_BLOCK
block of data. To start collection of the next data block the module must be armed and triggered
again. This mode is used whenever each block of data is to be associated with an individual
trigger event.
AGE1439_CONTINUOUS
runs continuously with no gaps between output data blocks. The measurement continues as long
as the data is read out fast enough to prevent overflow in the output FIFO. The continuous mode is
useful for continuous signal processing applications where data gaps are unacceptable.
modePtr
points to the current value of the mode parameter.
port
determines which output port is used to take data from the Agilent E1439 module.
Setting port to
This is the instrument default.
Setting port to
VXI local bus (Agilent E1439D only) . When using the local bus port the module immediately to
the right of the Agilent E1439 must be capable of receiving the local bus byte sequence.
Setting port to
stream over the fiber interface.
portPtr
points to the current value of the port parameter.
resolution
selects data resolution of either 12 or 24 bits by using resolution values of
AGE1439_24BIT
memory. Choosing 24 bits allows more dynamic range. Because of the broadband white noise
present on the input of the analog-to-digital converter, it is normally sufficient to use 12 bit
resolution whenever the age1439_filter_setup function specifies a signal bandwidth greater than
10 MHz. For narrower bandwidths much of the broadband white noise is filtered out, resulting in
lower noise in the output data. To take advantage of this lower noise, you should use the 24-bit
data resolution.
resolutionPtr
points to the current value of the resolution parameter.
Comments
The following table summarizes the output word or byte sequence for each combination of
dataType, resolution, and port parameters:
92
selects block transfer mode in which the measurement is halted after each
means that a single arm and trigger event starts a measurement which
AGE1439_VME
means the data is to be output using standard VME register reads.
AGE1439_LBUS
means the data is to be output as a byte-serial data stream via the
AGE1439_FIBER
means the filtered ADC data is to be transmitted as a serial data
respectively. Choosing 12-bit precision allows for more samples in the FIFO
AGE1439_12BIT
or

Advertisement

Table of Contents
loading

Table of Contents