Choosing an Installation Location

AUTOMATIC SYSTEM ACTIVATION HAZARD
Unexpected activation of the system could result in serious injury, including skin injection and amputation.
This device has an automatic timer that activates the pump lubrication system when power is connected or when exit-
ing the programming function. Before you install or remove the lubrication pump from the system, disconnect and iso-
late all power supplies and relieve all pressure.
Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
Refer to the two mounting hole layouts provided
in the Mounting Pattern section of this manual,
page 59.
NOTE: The two mounting hole layouts provided
in the Technical Data section show the only cor-
rect installation patterns to use for mounting the
G3. No other installation configurations should
be used.
3A0414B
Use designated mounting holes and provided
configurations only.
Always mount the G3 upright.
If the G3 is going to be operated in a tilted or
inverted position for any period of time, you
must use a model that includes a follower plate.
Refer to your model number to confirm if a fol-
lower plate was installed on your pump. See
page 4, Understanding the Model Number to
identify this character in your model number.
Use the three fasteners (included) to secure the
G3 to the mounting surface.