No Controller Operation
No Controller Operation
The G3 Pump can be controlled using an external, user
supplied, power source and controller.
Refer to the Typical Installation diagrams provided on
page 8 for correct location of the required pump ground
wire and fuses.
NOTE:
•
When using an external power source and control-
ler, Pump ON (Run) Time should be set for no lon-
ger than 30 minutes.
•
In most cases, Pump OFF (Rest) Time should be
twice as long as Pump ON (Run) time. If alternative
ON / OFF times are required, contact Graco Cus-
tomer Service for assistance.
Typical Low Level Output Response with Low Level Fluid
Closed
Contact
Position
Open
F
. 10
IG
28
Low Level Output Option
Some G3 pumps without controllers include a Low Level
Output Option. When the fluid level has reached a low,
warning level, PINS 3 and 4 momentarily close (1 time
per paddle revolution), sending the signal to the control-
ler that the fluid has reached a low level. For PIN 3 and 4
locations and wiring information, see the Low Level Out-
puts diagram, page 19.
To ensure a low level condition has been met, 3 or more
low warning level triggers must be detected within 1 min-
ute or less.
NOTE: A low level warning is triggered when the con-
troller detects PINS 3 and 4 have momentarily closed.
See F
. 10 for an illustration of a Typical Low Level Out-
IG
put Response with Low Level Fluids.
200 ms
3 s