Pro Model Setup
Pro Model Setup
Control Panel Overview (F
NOTE: Programming instructions begin on page 31.
DISPLAY
•
A blinking LED under HH, MM, SS or ##
indicates type of measurement unit you
are setting; i.e., HH is hours.
•
A blinking number on the display indi-
cates the G3 is in SETUP MODE.
•
In RUN MODE displayed numbers count
up or down. See Time ON and Time
OFF.
ON TIME
•
LED lights when ON Time
sequence is running.
•
Display shows time as MM:SS
(minutes and seconds).
i.e., 08:30 is 8 minutes: 30 sec-
onds.
•
Times lubrication cycle.
•
Counts down from a set time to
zero.
LEFT DIRECTION ARROW /
RESET
•
In SETUP MODE, moves cur-
sor in display one field to the
left.
•
In RUN MODE: single press
clears warning.
•
In ALARM MODE: pressing and
holding for 3 seconds clears
fault / warning and switches
cycle to OFF MODE.
F
. 11
IG
30
. 11)
IG
HH
MM
SS
##
ON
OFF
MM : SS
HH : MM
UP and DOWN ARROW
•
Hold both the UP and DOWN ARROW but-
tons down together for 3 seconds to enter
SETUP MODE.
•
In SETUP MODE, increases or decreases
number values shown in display.
OFF TIME
•
LED lights when OFF Time sequence is
running.
•
Value is entered in HH:MM.
•
Displays in HH:MM (hours and minutes)
when > 1 hour.
•
Displays in MM:SS (minutes and second)
when < 1 hour.
•
Times pump rest between cycles.
•
Counts down from set time to zero.
!
ALARM ICONS
LED next to icon lights when a
fault / warning event occurs dur-
ing a run cycle. See page 47 for
a complete description of these
alarm scenarios.
LOCK ICON
•
•
PRELUBE
LED next to icon lights indicat-
ing Prelube function is enabled.
RIGHT DIRECTION ARROW /
MANUAL RUN / ENTER:
•
In SETUP MODE, saves
entry, moves cursor in display
one field to the right or to the
next setup step.
•
In RUN MODE starts a man-
ual run cycle.
LED next to icon lights indi-
cating PIN is required to
enter setup.
In SETUP MODE LED
lights when setting up the
PIN.
3A0414B