Replacing Led Shelf Light Bars - Hussmann Impact Excel M5X Installation And Service Manual

Medium temperature meat, delicatessen, dairy and produce merchandisers
Hide thumbs Also See for Impact Excel M5X:
Table of Contents

Advertisement

P/N 0463880_E

REPLACING LED SHELF LIGHT BARS

The LED shelf light bars are held in place using a
magnetic surface on the back of the light bar.
P/N XXXXXXX
AM P/N XXXXXXX
COLOR TEMP: 2900 K
INPUT VOLTAGE: 24VDC
REPLACING LED POWER SUPPLIES
The LED power supplies for canopy lights and
shelf lights are located at the top of the merchan-
diser inside the canopy.
6 ft & 8 ft
LH Shelves
12 ft
LH Shelves
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
P/N 0501208
DATE CODE: XXXX
Label
BLU)
Detail
P/N 0501208
LED Shelf Light Bar
LED
Shelf Light Bar
Connector
RH Shelves
Center Shelves
Canopy and Shelf LED Power Supply Arrangement
1. D
ISCONNECT POWER TO THE MERCHANDISER
2. Remove light bars from the canopy.
3. Remove the screws that secure the lamp
panel.
4. Grasp the lamp panel at its front edge and
carefully pull down. It will swing freely from its
hinged rear edge.
5. Replace power supply and reassemble parts in
reverse order.
6. Reconnect the electrical power.
Power Supply
Canopy
RH Shelves
Medium Temperature
Canopy
Excel
6-3
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Impact excel m5ep

Table of Contents