When the results of check item (22) are "00"
(Detection of 5V is not OK.)
Check the +5V voltage. (Front HDMI Buffer)
Check item(24).
Check the +5V voltage.
Does "+5 V" at the following test point indicate 5 V?
The test points are as follows.
YES
HDMI Rx1 (U1000) is faulty.
Replace with a new device.
Recheck from
check item (3).
If it does not work, replace the PCB.
NO
Check for a short circuit in the 5 V line, the
Front HDMI FFC, and the 5 V Switch (U1002).
If there is no problem, the HDMI Rx (U1000) or
the 5 V Switch (U1002) is faulty.
Replace with a new device.
When the results of check item (23) are
"00 or
(If the DDC are not OK)
Check the DDC line. (Front HDMI Buffer)
Check item(25).
Check the DDC line :
Does "DDCCL / DDCDA" signal of the RX1 (U1000)
indicate 5 V?
The test points are as follows.
YES
HDMI Rx1 (U1000) is faulty.
Replace with a new device.
Recheck from
check item (3).
If it does not work, replace the PCB.
94
04"
less than 100KHz
5V
5V
This diagram shows an example of the DDC commu-
nication waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100 KHz or less.
Check at each test point.
NO
Check for a short circuit in the DDC line and
check the Front HDMI FFC.
If there is no problem, the Front HDMI
Buffer(U1022) is faulty.
Replace with a new device.