Marantz SR5011 Service Manual page 104

Hide thumbs Also See for SR5011:
Table of Contents

Advertisement

When the results of check item (42) are "00"
(Detection of HPD is not OK / Detection of RXSENSE is not OK )
Checking the HPD/RXSENSE status register. (Monitor2)
Check item(48).
Checking the HPD and RXSENSE. :
Does the test point of RXSENSE close to the HDMI output terminal
(N1030) indicate the 3.3 V?
Does the voltage of HPD test point close to the HDMI output terminal
(N1030) indicate Hi (3-5 V)?
YES
NO
Check for a short circuit in the TMDS/ HPD line.
If there is no problem, the HDMI Tx (U1039) is faulty.
Replace with a new device.
HDMI Tx (U1039) is faulty.
Replace with a new device.
Recheck from
check item (4).
If it does not work, replace the PCB.
104

Advertisement

Table of Contents
loading