Configuration for Positioning
Al ways de ac ti vate start com mand ST1/ST2 be fore start ing a new po si tion ing se quence.
Then you can se lect a new ta ble en try with DI0 - DI7 and start the po si tion ing se quence
with ST1/ST2.
Ta ble en tries are not re set when you re store the am pli fier's fac tory de fault set tings!
You do not need to turn the am pli fier off and on again af ter changing ta ble en tries.
NOTE
Please see the in struc tion man ual for full de tails on all these pro ce dures.
4.4.1

Import ing and export ing point tables

There are two dif fer ent ways to store the point table from your pro ject so that you can edit it again
later in exter nal pro grams and MR Configurator:
Export the point ta ble as a text file with the ex ten sion .ptb. This cre ates a plain text file that
can be ed ited with a nor mal text ed i tor.
Ex port the point ta ble as a file with the ex ten sion .csv. These files con tain data that can be
ed ited by spread sheet pro grams like Microsoft Ex cel.
Pro ce dure:
The Point Ta ble List win dow must be open and ac tive.
How to ex port the point ta ble to a file:
Fig. 4-16: Ex port ing the point ta ble to a file for ar chi val or editing