6.3.3.8.
Furnace G Terminal
This setup option selects desired operation when the R- - G circuit changes state on
the furnace control board depending on setup.
Under the function option, FAN turns on fan to selected fan speed when G terminal
is energized. SHUTDOWN shuts off fan and equipment when initiated.
After the selections are made, touch SAVE.
Function: Disabled, Fan or Shutdown
S
Default = Disabled
d
Fan Speed: Low, Med, or High
S
Default = Low
d
Shutdown:
S
Normally Open
d
Normally Closed
d
The shutdown function may not be immediate. Blower off delays, etc., will
d
still be used. The shutdown is not intended for commercial applications. If
immediate shutdown is required, provision must be made to remove power
to indoor unit.
45