Bryant Evolution Connex Control Installation Instructions Manual

Bryant Evolution Connex Control Installation Instructions Manual

Hide thumbs Also See for Evolution Connex Control:
Table of Contents

Advertisement

Quick Links

SYSTXBBECC01- -B
Evolutionr Connext Control
NOTE: Read the entire instruction manual before starting the installation.
NOTE: Please refer to the literature provided with the connected HVAC equipment
for more details on system operations with specific pieces of equipment.
The features and functions outlined in the Installation Instructions reflect Version 1.3 or
later software. Occupancy sensing compatibility is only available with Series B
Evolution Connex Controls. See the Evolution Connex product page on the
HVACPartners.com
www.MyEvolutionConnex.Bryant.com website for the latest software release and
literature.
US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452,
pointSETt U.S. Pat No. 7,415,102
Installation Instructions
website
or
the
Downloads
section
A170204B
of
the

Advertisement

Table of Contents
loading

Summary of Contents for Bryant Evolution Connex Control

  • Page 1 Evolution Connex Controls. See the Evolution Connex product page on the HVACPartners.com website Downloads section www.MyEvolutionConnex.Bryant.com website for the latest software release and literature. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452, pointSETt U.S. Pat No. 7,415,102...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PAGE 1.Safety Considerations ..........2.Introduction .
  • Page 3 TABLE OF CONTENTS (cont.) PAGE 4.5. Decorative Trim Plate ........4.5.1.
  • Page 4 TABLE OF CONTENTS (cont.) PAGE 6.Service Menu ........... 6.1.
  • Page 5 TABLE OF CONTENTS (cont.) PAGE 6.3.3. Furnace ..........6.3.3.1.Furnace Airflow .
  • Page 6 TABLE OF CONTENTS (cont.) PAGE 6.3.4.9.Low Air Multiplier ........6.3.4.10.Energy Efficiency .
  • Page 7 TABLE OF CONTENTS (cont.) PAGE 6.3.10. Utility Curtailment ........6.3.11.
  • Page 8 TABLE OF CONTENTS (cont.) PAGE 6.5. Service Information ......... . 6.5.1.
  • Page 9 TABLE OF CONTENTS (cont.) PAGE 6.7. Dealer Logo ..........6.8.
  • Page 10: Safety Considerations

    1. Safety Considerations Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury or property damage. Consult a qualified installer, service agency or your distributor or branch for information or assistance. The qualified installer or agency must use factory- - authorized kits or accessories when modifying this HVAC system.
  • Page 11: Introduction

    Also, the NIM allows connection of a Bryant HRV or ERV without the need for separate wall control. When using a Bryant HRV or ERV with a zoned system, the Evolution System Zone board allows connection of a Bryant HRV or ERV without the need for separate wall control or NIM.
  • Page 12: Quick Start

    3. Quick Start NOTE: See Section 4 for installation instructions. 3.1. Set Time and Date The time and date can either be set manually or can be synchronized with the web server (only for Wi- - Fi enabled units). From the main screen, touch MENU, on the bottom of the control.
  • Page 13: Setup Time Zone

    3.1.2. Setup Time Zone The time zone can be selected by selecting the set time zone from the menu. Then select the time zone for the location. Time zones for both US and Canada are included. A14217 3.1.3. Enable Time Synchronization ®...
  • Page 14: Set Dealer Information

    From the main screen, touch MENU, on the bottom of the control, then Down (B) button so that the SERVICE icon is shown. The SERVICE icon allows you to upload your contact information into the Evolution Connex Control. A170243B Format your contact information and logo (if applicable) using the PC/MAC Desktop application available at www.MyEvolutionConnex.Bryant.com/Evolution/Downloads, and save it to a...
  • Page 15: Installation

    4. Installation 4.1. Overview This instruction covers installation of the Evolution Connex Control and the Evolution Wireless Access Point only. Physical installation instructions for the indoor and outdoor equipment, and accessories are provided with each unit. Setup, commissioning, operation, and troubleshooting of the Evolution System are covered in this installation instruction at a high level.
  • Page 16: Location

    4.3.1. Wall Control The Evolution Connex Control is the command center for the Evolution System. It should be located where it is easily accessible and visible to the adult homeowner or end user. For accurate temperature measurement, the following guidelines should...
  • Page 17: Remote Room Sensors

    4.3.2. Wired Remote Room Sensors A Remote Room Sensor can be used with the Evolution Connex Control to take the place of the control’s internal temperature sensor. This allows the Evolution Connex Control to be mounted in areas with less than optimal airflow (such as near an exterior door, window or in a closet).
  • Page 18: Smart Sensors (For Zoning Applications)

    It also displays outdoor temperature and indoor humidity sensed at the Zone 1 Evolution Connex Control. Only one Smart Sensor may be used per zone. They cannot be averaged like Remote Room Sensors. If a Smart Sensor is used in a zone, one wired Remote Room Sensor may also be used in the same zone.
  • Page 19 NOTE: ABCD bus wiring only requires a four- - wire connection; however, it is good practice to run thermostat cable having more than four wires in the event of a damaged or broken wire during installation. Each communicating device in the Evolution Zone System has a four- - pin connector labeled ABCD.
  • Page 20: Shielded Wire And Communication Bus Configuration

    C terminal, or ground, at the indoor unit. The shield wire should NOT be connected to any terminal at the Evolution Connex Control. Connecting the shield to ground at both ends can cause current loops in the shield, reducing shield effectiveness.
  • Page 21: Damper Control Module

    ”Daisy chain” wiring, where each communicating component is wired one after another, rather than all components connecting a in ”star” fashion to one point, is preferred. For wiring runs over 100 feet, terminating with a 100 ohm resistor at each end of the chain can help to avoid or mitigate electrical noise problems. 4.4.2.
  • Page 22: Decorative Trim Plate

    Align the trim plate around the backplate, and snap on the system control. A12213 NOTE: Once the Evolution Connex Control is secured to wall with the backplate assembly (snapped together), care must be taken not to bend or break the interlocking tabs when removing.
  • Page 23: System Control Mounting

    Route wires through large hole in mounting plastic. The hole may be enlarged, if required, to accommodate existing installations; avoid opening the wire hole more than necessary. Level backplate against wall (for aesthetic value only; the Evolution Connex Control need not be level to operate properly) and mark wall...
  • Page 24 Air leaking from behind the wall can affect measured temperature and humidity, and can affect operation. Attach Evolution Connex Control to the mounting plastic by lining up the plastic guides on the back of the control with the opening on the mounting plastic and push on.
  • Page 25: Humidifier Connections

    (DPST) MUST be used to prevent mixing the internal humidifier power with the indoor equipment transformer. Applying 24VAC isolation relay coil to furnace or fan coil HUM and COM terminals will allow the Evolution Connex Control to automatically energize the HUM output during a call for humidification. The N.O.
  • Page 26: Commissioning

    “Searching for outdoor unit.” If it is not corrected, the Evolution Connex Control will go into its DEMO operating mode. If a control is operating in Demo mode and you wish to install it with equipment, navigate to the Installer menu and perform a re- - install to re- - learn the equipment.
  • Page 27: Searching For Outdoor Unit

    A12178 5.2. Searching for Outdoor Unit The Evolution Connex Control will then proceed to communicate with the outdoor unit by displaying “Searching for outdoor unit”. This includes Evolution small packaged products (SPP) and Evolution System geothermal units. NOTE: If the outdoor unit cannot be found, the control will display “Outdoor unit not found”.
  • Page 28: Indoor Evaporator Selection

    19VS air conditioner, a screen will appear to select the installed indoor evaporator coil. This selection is used to adequately calculate the refrigerant charge required while in the heat pump charging screens under Refrigerant Charging, Section 6.6. Select “other” for non- - Bryant evaporators. 5.4. Electric Heater Selection If the indoor equipment is a fan coil, the control will display “Searching for heater”...
  • Page 29: Hydronic Heat Application

    5.4.1. Hydronic Heat Application The Evolution Connex Control supports two types of Hydronic Heat applications: 1. Hot water coil in combination with an FE fan coil and heat pump, or hot water coil as sole heat source with an FE fan coil.
  • Page 30: Searching Sam Module (If Applicable)

    SYSTXBBRCT01 and SYSTXBBRWF01. The SAM is used for home automation purposes and is NOT used to connect the system control to the Internet. The Evolution Connex control must have at least Version 8 software or newer to be compatible with the SAM.
  • Page 31: Searching For Zones (If Applicable)

    5.6. Searching for Zones (If Applicable) “Zoning - - Searching” will appear on the screen to determine if any zones are present. The screen will show Zone 1, Zone 2, etc. and indicate all zones having either a Remote Room Sensor, or smart sensors associated with them. If the system contains smart sensors, they must be assigned a zone number before continuing.
  • Page 32: Ultraviolet Lights Installation

    5.9. Ultraviolet Lights Installation Next, the installer will be prompted to select whether ultraviolet lights are installed in the system. Select YES or NO, then touch NEXT. 5.10. Equipment Summary The equipment summary screen will appear after accessories have been selected. This screen will give a summary of all equipment automatically found or manually selected.
  • Page 33: Duct Assessment (Zoned Systems Only)

    TrueSenset dirty filter detection operation will not be affected. Press NEXT when the airflow verification check is complete. If the system has an indoor unit equipped with an updated- - version CFM- - controlled blower system (typically found in equipment manufactured after November 2017), the screen will display the static pressure (in inches) across the equipment at a pre- - determined target airflow CFM.
  • Page 34 At the end of the process, the display will show the relative size of each zone duct. If the Evolution Connex Control detects an error (damper not moving or damper wired backwards), it will perform the duct assessment again. If it still detects a damper problem, it will default the measurements into equal sizes, with 10% leakage, and display the zone number for the suspected zone damper.
  • Page 35: Service Menu

    6. Service Menu The Service menus contain a set of vital information. This information enables the installer or service person to view a summary of what has been installed, etc. This information is not covered in the Owner’s Manual. To enter service menus, touch menu, then touch and hold the SERVICE icon, for at least ten seconds, until the icon turns green.
  • Page 36: Equipment Summary

    A170181B 6.1. Equipment Summary Touch EQUIPMENT SUMMARY to show indoor unit type and model number, outdoor unit type (and model number if a 2- - stage unit), filter type, any accessories that are installed, and the number of zones in the system. To return to the previous screen, touch BACK.
  • Page 37: Installation

    Example: SPP Equipment Summary Screen A13121B 6.2. Installation Touch INSTALLATION to perform the start- - up process in order to learn all equipment in system. Select FULL INSTALLATION, then touch NEXT to initiate the process. Touch Airflow Verification Test to perform a duct assessment. This can be done if duct modifications have been made since installation of the Evolution Connex Control.
  • Page 38: Set Up

    NOTE: For Small Packaged Products (SPP), please use the following instructions for Set- - up (Section 6.3), Checkout (Section 6.4), and Service (Section 6.5): - - For PAC AC Indoor and OAC HP Indoor, follow Fan Coil instructions. - - For Gas PAC Indoor and Gas PHP Indoor, follow Furnace instructions. - - For all PAC Outdoor, follow AC/Heat Pump instructions.
  • Page 39: Thermostat

    Once the equipment has been selected, the appropriate menus will be displayed. 6.3.1. Thermostat First touch SETUP, then touch THERMOSTAT to set up the parameters for the Evolution Connex Control. 6.3.1.1. Auto Mode set up Once the auto changeover option has been selected, touch SAVE.
  • Page 40 Simultaneous Heat/Cool: Choose to turn simultaneous heat cool demand feature on or off. Default = Off If Simultaneous Heat/Cool is turned ON, Auto changeover time is grayed out and shows N/A. If Simultaneous Heat/Cool is turned OFF, Auto changeover time: Adjustable from 5 to 120 minutes Default = 30 minutes NOTE: AUTO mode is intended to switch between Heating and Cooling modes...
  • Page 41: 2.Heat/Cool Deadband

    6.3.1.2. Heat/Cool Deadband The minimum difference enforced between heating and cooling desired temperatures. The deadband does not change when the user changes between Fahrenheit (_F) and Celsius (_C). Ex: A 2_ deadband will be 2_F or 2_C and does not change with units, _F and _C. This can allow one setting to “push” the other to maintain this difference.
  • Page 42 Outdoor temperature: Adjustable from - - 5 to 5_F (- - 3 to 3_C) Default = 0_F Indoor temperature: Adjustable from - - 5 to 5_F (- - 3 to 3_C) Default = 0_F Humidity: Adjustable from - - 10 – 10% Default = 0% NOTE: For single- - zone systems, the indoor temperature offset is on this screen.
  • Page 43: 4.Reset Factory Defaults

    6.3.1.4. Reset factory defaults This option allows the installer to reset certain factory parameters. After the selections are made, touch SAVE. Program Schedule: Reset back to pre- - programmed time and temperature. User Settings: Reset user settings back to pre- - programmed values. Install Settings: Reset installation settings back to pre- - programmed values.
  • Page 44: 6.Smart Recovery On/Off

    6.3.1.6. Smart Recovery On/Off NOTE: ”Smart Recovery” refers to transitions between and among the Home, Sleep and Wake modes. Moving from the Away mode to any other mode is covered by the ”Advanced Smart Setback” feature. Smart Recovery applies to programmable operation only. Smart Recovery causes the system to ramp the system target setpoints to those for the next programmed schedule period to help save energy during period transitions.
  • Page 45: Fan Coil

    6.3.2. Fan Coil First touch SETUP, then touch FAN COIL to set up the parameters for the fan coil unit. A14223 6.3.2.1. Airflow This option allows the installer to select the appropriate air flow based on the needs of the installation. The QUIET airflow means the minimum cooling airflow that the system can safely run (typically 300 CFM/ton).
  • Page 46: 2.Altitude

    NOTE: For Geothermal Heat Pumps, the airflow labels have been changed from EFF325 and EFF350 to EFF1 and EFF2, respectively. Nominal geothermal system airflows for these settings tend to be different than the typical 325 and 350 CFM/ton values. The dehumidify airflow, when set to NORMAL, is allowed to adjust to a minimum to satisfy the dehumidification call.
  • Page 47 function to run longer, greatly improving humidity control in cooling mode. Accumulated electrical energy used while reheating (in kilowatt- - hours) is shown on the Fan Coil Run Hours screen and can be reset there. This option is only available with fan coil systems. Self- - identifying (staging) heaters provide the best performance for re- - heat dehumidification.
  • Page 48: 5.Fan Coil G- - Terminal Alert

    The shutdown function may not be immediate. Blower off delays, etc., will still be used. The shutdown is not intended for commercial applications. If immediate shutdown is required, provision must be made to remove power to indoor unit. A13229 6.3.2.5. Fan Coil G- - Terminal Alert Use the alert function to select the contact state for an alert.
  • Page 49: 6.Fan Coil G- - Terminal Label

    Shutdown: This setup option selects the change of state required for shutdown. . Select Normally Open or Normally Closed, and then save your selection. A13231 6.3.2.6. Fan Coil G Terminal Alert Label Once the G Terminal Alert label has been entered, it is shown both on the main screen and in the notification email when the alert becomes active.
  • Page 50: Furnace

    6.3.3. Furnace First touch SETUP, then touch FURNACE to set up the parameters for the furnace unit. A14225A 6.3.3.1. Furnace Airflow Selects the airflow of the furnace when heating. EFFICIENCY is the airflow used to meet specified ratings, COMFORT is a decreased airflow used to increase the output air temperature and provide increased comfort.
  • Page 51: 2.Ac/Hp Airflow

    6.3.3.2. AC/HP Airflow NOTE: For Geothermal Heat Pumps, this option will be shown as ’Geo HP’ airflow. This option elects the airflow of the furnace when cooling, heat pump heating, and dehumidification when used with a geothermal heat pump. The QUIET airflow means the minimum cooling airflow that the system can safely run (typically 300 CFM/ton).
  • Page 52: 3.Furnace Staging

    After the selections are made, touch SAVE. Cool: Quiet, Comfort, EFF325 (or EFF1), EFF350 (or EFF2), or Max Default = Comfort HP Heat: Comfort, EFF325 (or EFF1), EFF350 (or EFF2), or Max Default = Comfort Dehumidify: Normal or High Default = Normal 6.3.3.3.
  • Page 53: 5.Furnace Off Delay

    Max. modulating limits: Maximum CFM to run a modulating furnace. This will increase the maximum operating capacity of the furnace. Default value is the furnace air flow for the highest heat capacity 6.3.3.5. Furnace Off Delay This option denotes the amount of time the blower will continue to run after heating has shut off.
  • Page 54: 8.Furnace G Terminal

    6.3.3.8. Furnace G Terminal This setup option selects desired operation when the R- - G circuit changes state on the furnace control board depending on setup. Under the function option, FAN turns on fan to selected fan speed when G terminal is energized.
  • Page 55: 9.Furnace G Terminal Alert

    6.3.3.9. Furnace G- - Terminal Alert Use the alert function to select the contact state for an alert. Select Normally Open or Normally Closed, and then save your selection. A13230 Shutdown: This setup option selects the change of state required for shutdown. Select Normally Open or Normally Closed, and then save your selection.
  • Page 56: Ac/Heat Pump

    6.3.4. AC/Heat Pump First touch SETUP, then touch AC/HEAT PUMP to set up the parameters for the AC/Heat Pump unit. NOTE: For Geo HP setup, see Sec 6.3.7. A14227A 6.3.4.1. Latching (Not available for geothermal units) High Cool Latch A13227A...
  • Page 57 System in Control The system will decide which stage should be running to satisfy the cool- ing demand. High Cool Temperature above which only the high stage of cooling will be energized. Only Low Cool The system will only run in low stage cooling. High Heat Latch A13228 System in Control...
  • Page 58: 2.Cooling Lockout

    6.3.4.2. Cooling Lockout Outside temperature below which cooling will not be provided. After the selection is made, touch SAVE. Cooling Lockout Temp: None, 45, 50 or 55 (_F) Default = None NOTE: When simultaneous heating and cooling demand feature is on, the cooling lockout shall be ignored.
  • Page 59: 5.Quiet Shift

    6.3.4.5. Quiet Shift This option turns on Quiet Shift function in 1- - stage or 2- - stage communicating heat pumps. After the selection is made, touch SAVE. NOTE: This option is not available with variable speed heat pumps nor geothermal units.
  • Page 60: 9.Low Air Multiplier

    6.3.4.9 Low Air Multiplier Adjusts the airflow speed on non- - communicating two- - stage units. Choose 0.65 for units with a Bristol compressor, choose 0.80 (default) for units with a Copeland scroll compressor. 6.3.4.10. Energy Efficiency This option is used to input the published ratings of the installed air conditioner or heat pump as part of the energy tracking calculation.
  • Page 61: Stages / Latch For 18Vs

    Furnace, Electric Heat or Hydronic Lockout: Adjustable from 15 to 55_F (- - 9 to 13_C) or None Default = None Defrost with Furnace, Electric Heat or Hydronic: Yes or No Default = Yes For Geothermal units, lockout for auxiliary heat (furnace or electric resis- tance) is not enabled.
  • Page 62: Geo Hp

    6.3.7. Geothermal HP First touch SETUP, then touch Geo HP to set up the parameters for the Geo HP unit. A160188B...
  • Page 63: 1.Freeze Limits

    6.3.7.1. Freeze Limits This setting controls the temperature level to which the loop liquid can drop before the Geo HP unit will stop operating. See the Geo HP Installation Instructions for more details. Typically, 26_F is chosen for open- - loop systems using untreated water;...
  • Page 64: 2.Lockout Count

    6.3.7.2. Lockout Count This setting controls the number of times within an hour that the HPS or LPS trips before the Geo HP compressor will lockout for four hours. After the selection is made, touch SAVE. Lockout Count: 4 or 2 Default = 2 A150180...
  • Page 65: 3.Brownout Override

    6.3.7.3. Brownout Override This option controls the low voltage brownout override function in the Geo HP unit. After the selection is made, touch SAVE. Brownout Override: Active or Inactive Default = Inactive A150181 6.3.7.4. Geothermal HP Energy Tracking Energy tracking for geothermal heat pumps requires the installation of an Entering Water Temperature (EWT) sensor.
  • Page 66: Zoning (If Applicable)

    6.3.8. Zoning (If Applicable) First touch SETUP, then touch ZONING to set up the parameters for the zoning system (if applicable). A12191 6.3.8.1. Disable Zoning This option allows the installer to enable or disable zoning. After the selection is made, touch SAVE. Disable Zoning: Yes or No Default = No 6.3.8.2.
  • Page 67: 3.Zone Airflow Limits

    6.3.8.3. Airflow Limits Since a bypass damper is prohibited in this system, this setting is used to select the maximum allowable noise/airflow relationship into each zone based on air noise and comfort requirements. LOW means 100% of maximum assessed airflow; MED- - LOW means 138% of maximum assessed airflow;...
  • Page 68: Accessories

    6.3.9. Accessories First touch SETUP, then touch ACCESSORIES to set up the parameters for the accessories installed with the system. A12192 6.3.9.1. Filter NOTE: The daily duct assessment will occur even if static pressure monitoring is disabled. This is done to ensure that the system will continue to provide proper airflow for all installed equipment, since duct system changes may occur at any time, such as opened or closed registers.
  • Page 69: 2.Humidifier

    6.3.9.2. Humidifier With this option, the installer has the option of selecting whether a humidifier is installed, to humidify with the fan in low speed, and the time interval for changing the humidifier pad. After the selections are made, touch SAVE. Humidifier Installed: Yes or No Humidifier selection made during installation;...
  • Page 70: Utility Curtailment

    6.3.10. Utility Curtailment NOTE: Utility Curtailment and Utility Saver functions are different than the Utility Demand Response function described in the Owner’s Manual. Utility Curtailment/Utility Saver uses the UTIL and Y2 (or equivalent) terminals on the Evolution System compressor section control board to receive a dry contact relay signal from the Utility, typically from the electric meter assembly, to signal a curtailment period.
  • Page 71: Hydronic Airflow

    Cooling: Disabled, Low Stage or Turn off Default = Disabled Heat Pump: Disabled, Low Stage or Turn off Default = Disabled 6.3.11. Hydronic Airflow NOTE: The daily duct assessment will occur even if Hydronic Airflow is set to Off. This is done to ensure that the system will continue to provide proper airflow for all installed equipment, since duct system changes may occur at any time, such as opened or closed registers.
  • Page 72: Check Out

    6.4. Check out WARNING PROPERTY DAMAGE AND/OR PERSONAL INJURY HAZARD Failure to follow this warning could result in property damage, personal injury or death. Before running Check Out mode, make sure that all HVAC equipment is properly installed. See the equipment installation instructions for details and additional safety information.
  • Page 73: Electric Heat

    6.4.1. Electric Heat If you have a fan coil with electric heaters, this menu item will allow the heaters to be exercised. With self- - identifying electric heaters, three stages of electric heat are available to be exercised in any combination. Non- - identifying heaters will only provide one stage of heat;...
  • Page 74: Hydronic

    6.4.3. Hydronic This option allows the hydronic heat relay to be exercised. First, it will energize the relay and turns on the blower. This sequence will be displayed on the screen. After the selections are made, touch START. Hydronic heater check: Selectable from 0 to 120 minutes Default = 5 minutes 6.4.4.
  • Page 75: Heat Pump Heating

    6.4.5. Heat Pump Heating The heat pump heating mode can be exercised with this menu option. With a 2- - stage heat pump, a Low Heat and a High Heat Run Time are independently selectable to exercise. For variable speed heat pumps, you can select the speed at which the heat pump will exercise.
  • Page 76: Heat Pump Cooling

    6.4.6. Heat Pump Cooling The heat pump cooling mode can be exercised with this menu option. With a 2- - stage heat pump, a Low Cool Run Time and a High Cool Run Time are independently selectable to exercise. For variable speed heat pumps, you can select the speed at which the heat pump will exercise.
  • Page 77: Ventilator

    6.4.8. Ventilator The ventilator can be exercised through all of its operating speeds with this menu option. To end the ventilator checkout, touch STOP. Humidifier Check: High, Low or Off NOTE: This option may NOT available with the ERVXXNVA ventilator due to its simplified control design.
  • Page 78: 2.Damper/Sensor Check

    6.4.9.2. Damper/Sensor Check The Sensor/Damper Check allows the installer to check each zone damper for operation, as well as insure the zone sensor corresponds to that particular zone. When first initiated, the Zone 1 damper will fully open, and all other zones will close.
  • Page 79: 4.Sensor Type

    6.4.9.4. Sensor Type This option shows a list of all zones with corresponding sensor types. 6.5. Service Information The Service Info menu will only show the equipment installed in the system. To enter this menu of options, touch SERVICE INFORMATION. A13123A 6.5.1.
  • Page 80: Fan Coil Status

    6.5.2. Fan Coil Status The fan coil status screen displays relevant information about the fan coil operation. To return to the previous screen, touch BACK. To exit the Service menus, touch DONE. A12197 6.5.3. Furnace Status The furnace status screen displays relevant information about the furnace operation. To return to the previous screen, touch BACK.
  • Page 81: Ac Status

    6.5.4. AC Status The AC status screen displays relevant information about the AC operation. To return to the previous screen, touch BACK. To exit the Service menus, touch DONE. A12199 6.5.5. Heat Pump Status The heat pump status screen displays relevant information about the heat pump operation.
  • Page 82: Geo Hp Status

    6.5.6. Geothermal HP Status The Geo HP status screen displays relevant information about the Geo HP operation. To return to the previous screen, touch BACK. To exit the Service menu, touch DONE. A160192 6.5.7. Zoning Status The zoning status screen displays relevant information about the zoning operation. To return to the previous screen, touch BACK.
  • Page 83: Last 10 System Events

    6.5.8. Last 10 System Events This screen will show the last 10 events that occurred throughout the system. Each entry has the time and date incident recorded. These events are stored in the memory of the control and are resettable in the THERMOSTAT SETUP screen under the RESET FACTORY DEFAULT selection.
  • Page 84: Run/Fault History

    6.5.9. Run/Fault History This information is stored in the equipment circuit boards (if communicating) and displayed on the control. The indoor unit and outdoor unit (if communicating) have the following histories. To return to the previous screen, touch BACK. To exit the Service menus, touch DONE.
  • Page 85: Service Phone Number

    A14230 6.5.11. Service Phone Number This menu item allows the installer to view the name and phone number that the homeowner can call for future service of the system. This name and phone number will appear to the homeowner whenever a service reminder pop- - up message is displayed (i.e.
  • Page 86: Refrigerant Charging: Greenspeed, 18Vs, 19Vs Systems

    This menu item allows the installer to view the energy usage of each piece of equipment connected to the system. To return to the previous screen, touch BACK. To exit the Service menus, touch DONE. A14231 ® Refrigerant Charging: Greenspeed Intelligence, 18VSt, 19VSt Systems For variable capacity and multi- - stage heat pumps and AC units, a refrigerant...
  • Page 87: Charging

    NOTE: See the outdoor equipment Installation Instructions for information on what conditions CHARGING COOLING and HTG CHECK CHARGE are available. A14232 6.6.1. Charging Within the CHARGING COOLING or HTG CHECK screens, the installer will have the ability to enter the LINESET length and the VAPOR LINE diameter. After the selections are made, touch NEXT.
  • Page 88 Next, the installer will enter the SERVICE VALVE INFORMATION screen. The current liquid line subcool target, stabilization time, mode and speed in rpm, EXV position in percent, indoor airflow in CFM, outdoor coil temperature in _F, indoor temperature in _F, outdoor temperature in _F, compressor discharge pressure in psig, and accumulator suction pressure in psig are displayed on this screen.
  • Page 89: Pump Down

    Set desired time period. Default time period for procedure is 120 minutes. Touch START on Evolution Connex Control or service tool to open the valve. Begin evacuation or refrigerant recovery as required for the procedure after control indicates the EXV is open. Power may be removed from heat pump...
  • Page 90: Exv Position

    Product tab> Thermostats & Controls> SYSTXBBECC01> Documents & Downloads> Marketing/Miscellaneous> Evolution Connex Control Dealer Logo Application - - Instructions. Touch DEALER LOGO to upload the dealer logo and contact information from a standard SD card connected to the Evolution Connex Control. The “Dealer Logo Application” PC/MAC Desktop...
  • Page 91 Once the dealer logo and contact information have been properly loaded onto the SD Card, insert the SD card into the bottom edge of the Evolution Connex Control. The control will prompt you whether or not to upload the dealer logo. Once complete, you will receive a confirmation that your upload was successful.
  • Page 92: Utility Event Setup

    If you have problems, contact your distributor service manager for support. A170253 6.8. Utility Event Setup The utility event setup is used to enable utility events if the home owner is participating in a utility event program. Selecting ON will enable the utility event icon on the main menu.
  • Page 93: Wireless Setup

    Control, and/or the MyEvolution web server, with, and the availability of, the user’s Internet service provider or mobile device carrier service, or that the ability to remotely access and adjust the settings of the Evolution Connex Control will not be negatively affected by the network- related modifications, upgrades, or similar activity of the user’s Internet service provider or mobile device carrier...
  • Page 94: Setup And Status Information (Homeowner's Router)

    7.1 Setup and Status Information (Homeowner’s Router) To establish Wi- - Fi connectivity to the Evolution Connex Control using the in- - home router or wireless access point the wireless access point SSID and password/passkey must be known for set- - up.
  • Page 95 On the next screen look for the SSID of the router/access point. After being selected, it will be outlined in faint blue and indicated by a check mark. Then select NEXT. A150175 The selected network will show. Choose an appropriate Wi- - Fi network security mode.
  • Page 96 A13238 After the control has connected to the network, go to www.MyEvolutionConnex.Bryant.com to register the unit and begin remote access. This requires the MAC address and serial number of the Evolution Connex Control. To find the serial number and MAC address of the Evolution Connex Control, click on Menu, Down Arrow, Wireless and View MyEvolution Registration Info.
  • Page 97: Setup And Status Information (Dealer- - Provided Router)

    TP- - LINK Wireless Access Point should not be used for other devices. The Evolution (TP- - LINK) Wireless Access Point should only be used for connection of the Evolution Connex Control(s) and is not intended to be used wired or wirelessly with any other devices.
  • Page 98 A170241B Select WIRELESS from the menu screen Make sure the Wi- - Fi network connection is enabled, by touching ENABLED. Touch SETUP A WI- - FI CONNECTION to begin the process. Next, touch SCAN FOR AVAILABLE ACCESS POINTS. A12115 Select the myHVACxxxxxx connection from the list, then touch NEXT (myHVAC is followed by the last 6 digits of your Wireless Access Point’s MAC address;...
  • Page 99 SSID & Security Key A12357 You may have to use the down arrow to scan to the next screen to find “myHVACxxxxxx”. A12116 Use the on screen keyboard to enter the Wi- - Fi network security key, then touch NEXT. Touch in the security key area, and the keyboard will appear.
  • Page 100 This requires the MAC address and serial number of the Evolution Connex Control, NOT the Wireless Access Point. To find the serial number and MAC address of the Evolution Connex Control, click on Menu, Down Arrow, Wireless and View My Evolution Info. This screen will provide the information...
  • Page 101 If you have any issues, please contact your servicing dealer. When the connection to the MyEvolution web server has been established, the status screen will show Connected for both the Wi- - Fi network and the server. (TP- - LINKr is a trademark of TP- - LINK Technologies Co., Ltd.)
  • Page 102: Wiring Diagrams

    8. Wiring Diagrams Variable-Speed Furnace/ Fan Coil Communicating AC, HP or GHP* User Interface Green - Data A Green Yellow - Data B Yellow White - COM White Red - 24VAC Optional Remote Room Sensor ABCD Humidifier Connections Connection Sensor (Optional) *NOTE: Some outdoor units do not require the “C”...
  • Page 103 Variable-Speed Furnace/Fan Coil User Interface Green - Data A Yellow - Data B ABCD White - COM Connection Red - 24VAC 1-Spd. Optional Remote Non-Communicating Room Sensor Humidifier Connection Y/Y2 Sensor A12354 Connection Diagram for Furnace or FE Fan Coil with 1- - Stage Air Conditioning...
  • Page 104 Variable-Speed Fan Coil User Interface Green - Data A Yellow - Data B ABCD White - COM Connection Red - 24VAC 1-Spd. Optional Remote Non-communicating Room Sensor Humidifier Connection Sensor A12355 Connection Diagram for FE Fan Coil with Non- - communication 1- - Stage Heat Pump...
  • Page 105 Indoor Communicating Unit AC or HP Zone Control User Interface & Smart Sensor(s) Green Yellow A B C D White A B C D A B C D Humidifier Connection Damper Control module Sensor (Optional) A04018 Zoning Connection for Communicating Indoor Unit with 2- - Stage Communicating Outdoor Unit NOTE: Some outdoor units do not require “C”...
  • Page 106 Indoor Unit Zone Control User Interface & Smart Sensor(s) Green Yellow A B C D White 1-Stage AC A B C D A B C D Humidifier Connection Damper Control Y/Y2 module Sensor A04019 Zoning Connection Diagram for Furnace or FE Fan Coil with Non- - Communicating 1- - Stage Air Conditioning...
  • Page 107 Variable-Speed Zone Control Fan Coil User Interface & Smart Sensor(s) Green Yellow A B C D White 1-Spd. HP A B C D A B C D Humidifier Connection Damper Control module Sensor A07149 Zoning Connection diagram for FE Fan Coil with Non- - communicating 1- - Stage Heat Pump...
  • Page 108 A160170 NIM Chart...
  • Page 109 A160171 Wiring Diagram Single- - Stage Non- - Communicating Heat Pump NIM...
  • Page 110 A160172 Wiring Diagram Two- - Stage Non- - Communicating Heat Pump NIM...
  • Page 111 FE Fan Coil or Variable Speed Furnace A07114 G Input Wiring for Blower Operation...
  • Page 112 FE Fan Coil or Variable Speed Furnace A07115 G Input Wiring for System Shutdown...
  • Page 113: Statement Information

    9. Statement Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 114 Pour se conformer aux limites d’exposition RF FCC et IC pour la population générale / l’exposition incontrôlée, l’antenne utilisée pour cet émetteur doit être installée pour assurer une distance de séparation d’au moins 20 cm de toutes les personnes et fonctionnant conjointement avec toute autre antenne ou émetteur. This Device complies with Industry Canada License- - exempt RSS standard(s).
  • Page 115 NOTES...
  • Page 116 Amazon Alexa is a trademark of Amazon, Inc. or its affiliates. The Bluetooth word mark and logos are owned by Bluetooth SIG, Inc. E2017 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Edition Date: 12/17 Catalog No: II--- SYSTXBBECC--- 03 / 997--- 017060--- 23--- R...

This manual is also suitable for:

Systxbbecc01-b

Table of Contents