Single-Speed Air Conditioner With Single-Stage Furnace—Model Ac Thermostat; Single-Speed Air Conditioner With 2-Stage Or Variable-Speed Furnace—Model Ac Thermostat; Single-Speed Air Conditioner With 2-Stage Or Variable-Speed Furnace—Model Hp Thermostat - Bryant TSTAT Installation And Start-Up Instructions Manual

Bryant installation and start-up instructions programmable thermoststate tstat
Table of Contents

Advertisement

MODEL AC
SINGLE-STAGE
SINGLE-SPEED
THERMOSTAT
FURNACE
AIR CONDITIONER
24 VAC HOT
R
R
FAN
G
G
HEAT STAGE 1
W/W1
W
COOL STAGE 1
Y/Y2
Y
Y
N/A
O/W2
N/A
Y1/W2
24 VAC COMM
C
C
C
N/A
B
S1
OUTDOOR
SENSOR
S2
CONNECTION
See note 1
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
A98485
→ Fig. 2—Single-Speed Air Conditioner with Single-
Stage Furnace—Model AC Thermostat
TWO-STAGE OR
MODEL AC
SINGLE-SPEED
VARIABLE-SPEED
THERMOSTAT
AIR CONDITIONER
FURNACE
24 VAC HOT
R
R
FAN
G
G
HEAT STAGE 1
W/W1
W/W1
COOL STAGE 1
Y/Y2
Y/Y2
Y
N/A
O/W2
W2
N/A
Y1/W2
HUM
24 VAC COMM
C
C
C
N/A
B
OUTDOOR
S1
SENSOR
See notes 1 and 6
S2
CONNECTION
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF OFF OFF
A98486
→ Fig. 3—Single-Speed Air Conditioner
with 2-Stage or Variable-Speed Furnace
—Model AC Thermostat
TWO-STAGE OR
MODEL HP
SINGLE-SPEED
VARIABLE-SPEED
THERMOSTAT
AIR CONDITIONER
FURNACE
24 VAC HOT
R
R
FAN
G
G
HEAT STAGE 1
W/W1
W/W1
COOL STAGE 1
Y/Y2
Y/Y2
Y
HEAT STAGE 2
O/W2
W2
N/A
Y1/W2
HUM
24 VAC COMM
C
C
C
N/A
B
OUTDOOR
S1
SENSOR
See note 2
S2
CONNECTION
ON
SUGGESTED DIP
SWITCH SETTINGS
A
B
C
D
OFF OFF
ON OFF
A98487
→ Fig. 4—Single-Speed Air Conditioner
with 2-Stage or Variable-Speed Furnace
—Model HP Thermostat
Page 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents