Installation examples
Cube installed on a combustible platform
Depending on material, refer table on previous page. The
platform could extend 150 mm or 100 mm maximum in front of
the fire. This is dimension E in the table.
The height of the platform would need to be at least 150 mm or
300 mm high. This is dimension F in the table.
Cube installed on a non-combustible floating hearth
Only requirement for non-combustible material is a 50 mm
clearance from the back of the fire to the wall.
If the material is rated 50 °C or below (above ambient) then:
50 mm clearance from the back of the fire to the wall
In front, hearth could extend 100 mm or 150 mm maximum,
this is dimension E in the table.
Freestander with plinth base installed on a wooden floor
Using the table on the previous page there would be no
restrictions except a 50 mm clearance from the back of the
fire to the wall. The plinth automatically gives the 240 mm
minimum clearance from the bottom of the fire to the wooden
flooring—this is dimension F in the table.
Cube installed in an alcove
If all materials are non-combustible then the only restrictions
are a 50 mm clearance from the back of the fire to the wall,
and that the material above the fire is the same as the material
to the side of the fire. The flue requires a 25 mm clearance.
If the material is rated 50 °C or below then the following applies:
It cannot be installed directly on the floor unless there is some
form of protection directly in front of the unit.
Side clearance needs to be at least 50 mm minimum
Side overhang (C) can only be 100 mm max. (D + 50 mm)
Overhang (A) is B-250 mm. B in this example is 500 mm, so the overhang can be 500-250 mm,
(A) can be 250 mm maximum.
An additional diagram can be found on p.35.
Novo freestanding installation guide: 13992-A 01-22 | 9