Rinnai Novo Cube Installation Manual page 33

Table of Contents

Advertisement

Elbow flue strap DV
Code: R3644
Flue supports for elbows
and offsets. Strap length
approximately 432 mm.
High wind vertical cowl protection kit
Code: R3655
For windy areas such as Wellington, coastal properties, and elevated properties on hills. Designed to wrap
around the vertical cowl (as pictured) to reduce wind entering the flue and causing disturbances. it is fitted
to the cowl, and can be retrofitted.
Construction - stainless steel
45° bend offset / rise dimensions
Offset
Wall strap DV
Code: R3647
Adjustable strap used in
installations to add lateral
support to the flue. Provides
a 50-200 mm clearance to
combustibles.
Flue pipe (length and code)
None (bend to bend)
150 mm
230 mm
300 mm
Installed
rise
450 mm
600 mm
900 mm
1200 mm
Offset
Installed rise
N/A
124 mm
288 mm
R3630
203 mm
369 mm
R3631
257 mm
423 mm
R3632
311 mm
477 mm
R3633
417 mm
584 mm
R3634
524 mm
692 mm
R3635
737 mm
908 mm
R3636
949 mm
1123 mm