2. Prepare services
For best results the gas and power can be supplied through the plinth and into the base of the fire.
The power will need to be hard wired.
Bring enough cable through the floor to reach at least 100 mm above the top of the plinth. Bring
the gas supply through to within approximately 50 mm of the top of the plinth, flare the pipe, and fit
the supplied flexi tube. This should be leak tested now as access through the back panel is limited
once the fire is installed. The alternative is to drill a hole in the back of the fire for the gas supply
and to remove the notch for the power cord.
3. Assemble outer plinth panels
Working on a flat surface assemble the outer plinth panels as shown. Take care to ensure the
plinth is square and that the top surfaces are flush with each other.
3. Fit panels to the base mounting plate
Fit the plinth to the base mounting plate by lifting the back edge of the plinth and sliding the front
edge under the front lip of the base plate, then setting the edge back down. Hold in place with
three screws.
Novo freestanding installation guide: 13992-A 01-22 | 19