2. Preparations for checking HDMI Switcher reception/transmission register
2-1. Necessary devices
1)
Check the product settings.
2-a) Player with an HDMI terminal
2-b) TV with an HDMI terminal (* NOTE : Do not use a computer monitor.)
3)
Windows PC
4)
Serial communication software "Termite.exe"
(Download the software from http://www.compuphase.com/software_termite.htm and install
it.)
5)
HDMI cable
6)
RS-232C Straight cable
7)
oscilloscope
2-2. Device Connection Method
Connect the TV and the AVR to the player using an HDMI cable and connect the AVR to the PC through
an RS-232C cable as shown in Figure 1.
5)
2-a)
1)
5)
2-b)
Figure 1. Device Connection Method
2-3. Device configuration method
PC settings : Execute the serial communication program, Termite.exe.
The serial port setup screen will be displayed.
6)
Configure the settings as shown in Figure 3 and click the "OK" button.
3)
92
After executing Termite.exe, click [Settings].
Figure 2. Screen After Executing Termite.exe
Port Configuration
Port: Select COM port of PC
Baud rate: 19200bps
Data bits: 8
Stop bits: 1
Parity: none
Transmitted text
Flow control: none
Select Append CR-LF
Forward: (none)
Check the Local Echo check box.
Figure 3. Serial Port Setup Screen