Marantz SR5014 Service Manual page 121

Av surround receiver
Hide thumbs Also See for SR5014:
Table of Contents

Advertisement

When the results of check item (3-14.4.) are "10"
(Detection of HPD is OK / Detection of RXSENSE is not OK )
Check the RXSENSE. (Monitor1)
Check item(3-14.8.).
Checking the RXSENSE :
Does the test point of RXSENSE close to the HDMI output terminal
[N1031] indicate the (3.3V)?
N1031
HDMI OUT
[MONITOR1]
YES
NO
Check for a short circuit in the TMDS line.
If there is no problem, the HDMI Tx [U1039] is faulty.
Replace with a new device.
HDMI Tx [U1039] is faulty.
Replace with a new device.
Recheck from
check item (3.3.).
If it does not work, replace the PCB.
When the results of check item (3-14.4.) are "20"
(Detection of HPD is not OK / Detection of RXSENSE is OK )
Check the HPD. (Monitor1)
Check item(3-14.9.).
Checking the HPD :
Does the voltage of HPD test point close to the HDMI output termi-
nal [N1031] indicate Hi (3-5V)?
N1031
HDMI OUT
[MONITOR1]
HPD
YES
NO
Check for a short circuit in the HPD line.
If there is no problem, the HDMI Tx [U1039] is faulty.
Replace with a new device.
HDMI Tx [U1039] is faulty.
Replace with a new device.
Recheck from
check item (3.3.).
If it does not work, replace the PCB.
121