Marantz SR5014 Service Manual page 116

Av surround receiver
Hide thumbs Also See for SR5014:
Table of Contents

Advertisement

When the results of check item (3-13.3.) are "00"
(Detection of 5V is not OK.)
Check the +5V voltage. (HDMI DDC Buffer)
Check item(3-13.5.).
Check the +5V voltage :
Does "+5 V" at the following test point indicate 5V?
The test points are as follows.
70pin
U1000
YES
HDMI Rx1 [U1000] is faulty.
Replace with a new device.
Recheck from
check item (3.2.).
If it does not work, replace the PCB.
NO
Check for a short circuit in the 5 V line, the
Front HDMI FFC, and the 5 V Switch [U1002].
If there is no problem, the HDMI Rx1 [U1000]
or the 5 V Switch [U1002] is faulty.
Replace with a new device.
When the results of check item (3-13.4.) are
(If the DDC are not OK)
Check the DDC line. (HDMI DDC Buffer)
Check item(3-13.6.).
Check the DDC line :
Does "DDCCL / DDCDA" signal of the RX1 [U1000]
indicate 5 V?
The test points are as follows.
74/75pin
U1000
YES
HDMI Rx1 [U1000] is faulty.
Replace with a new device.
Recheck from
check item (3.2.).
If it does not work, replace the PCB.
116
"00 or
04"
less than 100KHz
5V
5V
This diagram shows an example of the DDC communica-
tion waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100 KHz or less.
Check at each test point.
Voltage scale:2.0V/div
Time scale:40us/div
NO
Check for a short circuit in the DDC line and
check the FRONT HDMI Cable.
If there is no problem, the HDMI DDC Buffer
[IC201] is faulty.
Replace with a new device.

Hide quick links: