3. Update method when the DIGITAL PCB or network module is replaced (Using a USB flash drive)
3.1. File structure on USB flash drive
DIGITAL PCB or network module is replaced onto the USB flash drive in the following structure.
After unzipping the files, store them in the root of the same USB flash drive.
Model Area
Download from SDI
ALL
avr_40.prod.update.factory.xxxx.zip
USB flash drive root
+ avr_40.prod.update.factory
+ xxxxxxzz.ota-download
+ heos_40.prod.update.factory
xxxxxx : Model name
zz :
Region
3.2. Start the update.
NOTE :
• Remove the LAN cable from this unit when updating.
(Do not connect to a wired or wireless network.)
• The GUI menu setting details and image quality adjustment setting details are initialized when
Firmware Factory Restore is performed. Therefore, take a note of the setting details beforehand and
reconfigure the settings after update.
• Do not remove the USB flash drive until updating is completed.
• Do not turn off the power until updating is completed.
• It takes a maximum of approximately 25 minutes for update to complete.
Once an update is started, normal operations cannot be performed until it is completed.
(1) Press the power button to turn on the power.
(2) Wait for this unit to start up.
(3) Set the input source to HEOS Music.
Check that the display is as shown below.
Display(Main Display)
L1
HEOS
L2
–TuneIn Internet Radio
L2 : Content of the display is scrolled.
(4) Insert the USB flash drive into the USB port.
Download firmware
in USB flash drive.
or
No Network Connection
(5) USB Update starts automatically.
The Standby LED lights red.
Display during USB update (Main Display)
L1 Wait
L2
–––––
L1 Updating
L2 –––
xx%
L3
xxmin
L1 Update
L2 Complete
It takes a maximum of approximately 25 minutes for update to complete.
(6) The unit restarts when update is complete.
b When update is complete, the folder name on the USB flash drive changes to
done". To use the files again, delete the ".done" part.
(7) Execute Firmware Factory Restore.
While holding down buttons "M-DAX" and "TUNER PRESET CH +" simultaneously, press the power
button to turn on the power.
Display during Firmware Factory Restore(Main Display)
L1 Restore
L2 FW...
L1 Restore
L2 –––
xx%
L3
xxmin
L1 Complete
It takes approximately 15 minutes for Firmware Factory Restore to complete.
(8) Execute Service Region Settings.
See
"4. Update Method for Service Region
(9) Check that the version is the specified version. See
(10) If necessary, use OTA or the USB flash drive to update the firmware to the newest version.
b We recommend using the firmware update method using OTA.
See
"5. Normal Firmware Update Method from USB Flash
Method from
OTA"
173
"avr_40.prod.update.factory.
Settings"
"1. Version Display
Mode"
Drive" or
"6. Normal Firmware Update

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents