Electrical Considerations - Empire Comfort Systems White Mountain Hearth DVTL27FP90N-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

All wiring should be done by a qualified electrician and shall
be in compliance with all local, city and state building codes.
Before making the electrical connection, make sure the main
power supply is disconnected. the appliance, when installed,
must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the national
electrical code ansi/nFpa 70 (latest edition).
COMBUSTION
BLOWER
USER INTERFACE/
BATTERY HOLDER
AUX.
L
N
WHITE
BLACK
OPTIONAL BLOWER
BLACK
TO JUNCTION
WHITE
BOX
GREEN
The user interface/battery holder must be mounted within a distance
allowed by the attached 12 foot harness. As shipped, this harness is
already fed through a strain relief on the bottom of the component
access box and is attached to the User Interface/Battery Holder.
note: A one inch diameter hole should be use to pass wiring
through studs.
Page 14

electrical consiDerations

caUtion
DVLL27
LEARN
BUTTON
LOOP
FLAME SENSOR
L
N
G
IGNITOR
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
with wire nuts to the control module power leads already fed into
the junction box.
Attach black to black and white to white. The ground wire should
be attached to the green control module lead.
GREEN
ORANGE
YELLOW
GAS CONTROL VALVE
Figure 13
ELECTRICAL POWER TO UNIT
JUNCTION BOX / CONTROL MODULE
COMPONENT
ACCESS BOX
VERTICAL
FRAMING
MEMBER
Figure 14
PILOT
SPLIT FLOW SOLENOID
WHITE
ORANGE
USER INTERFACE/
BATTERY HOLDER
MUST BE INSTALLED
INTO WALL JUNCTION
USER INTERFACE
HARNESS
BOX. (ORANGE LOW-
VOLTAGE BOX
RECOMMENDED.)
33740-17-0120