Top Vent - Vertical Termination - Empire Comfort Systems White Mountain Hearth DVTL27FP90N-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

top Vent - Vertical terMination

no elbows
DiMensions
MiniMUM
10'
two elbows
eXaMple Vent rUns
initial pipe
a (Vertical)
lenGtH
4'-1"
4'-7"
12'-7"
24'-7"
28'-7"
Page 24
MaXiMUM
40'
Figure 37
B (Horizontal)
7'-6"
17' MAXIMUM
8'
20' MAXIMUM"
16'
15' MAXIMUM
28'
7'-6" MAXIMUM
32'
5' MAXIMUM
Figure 38
three elbows
note: Subtract 3 feet from the total horizontal measurement for
each 90° elbow installed horizontally. Subtract 1-1/2 feet from the
total horizontal measurement for each 45° elbow installed hori-
zontally.
eXaMple Vent rUns
initial pipe
a (Vertical)
lenGtH
3'-7"
4'-7"
8'-7"
12'-7"
24'-7"
B (Horizontal)
7'
11'-6" MAXIMUM
8'
17' MAXIMUM
12'
14'-6" MAXIMUM
16'
12' MAXIMUM
28'
4'-6" MAXIMUM
Figure 39
33740-17-0120