NOTICE: Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
NOTICE: When installing this appliance against an exterior wall, insulate to applicable insulation codes.
When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions, a minimum of 6 inches clearance must be
maintained from the perpendicular wall and the front edge of the appliance.
All wiring should be done by a qualified electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The appliance,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
A factory installed junction box is located on the lower right side of
the fireplace. Wiring must be fed to the junction box and attached
to the receptacle that is provided. Leave approximately 6 inches of
wire in the junction box for connection.
Page 14

LOCATING FIREPLACE

ELECTRICAL CONSIDERATIONS

CAUTION
Figure 11
Attach black wire to brass colored screw on the receptacle and white
wire to the silver colored screw on the receptacle. The ground wire
should be attached to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
Figure 12
41412-0-0120