6

FAULT DIAGNOSTICS

6.1

Test program / fault (error) codes

1. Selecting the test program
Activate test
Set program selector switch to OFF position
program:
Press MENU + SELECT buttons for at least 3s
set program selector to Permanent Press Cold program:
Select test
Push MENU button to scroll through tests
program:
-P:01
-> Errors (see 2.)
-P:02
-> Safety test (see 3.)
-P:03
-> Automatic test sequence (see 4.)
-P:04
-> Motor (see 5.)
-P:05
-> Variant (not implemented, see 6.)
-P:06
-> Display (see 7.)
-P:07
-> Buttons and selector switch (see 8.)
-P:08
-> Pressure sensor (see 9.)
-P:09
-> Pressure switch (see 10.)
P:12
-> Update (see 12.)
P:13
-> Valves (see 13.)
P:14
-> Buzzer (see 14.)
P:15
-> Pump (see 15.)
P:16
-> Heater (see 16.)
P:17
-> Noise (see 17.)
Start test
Press START/PAUSE button
program:
Abort test
Press MENU button or set program selector to Off position
program:
Press START/PAUSE button at:
- Errors (see 2.)
- Variant (not implemented, see 6.)
Fault in test
program:
Leave test
Switch off device
program:
2. Errors
Display *
Fault/
Remarks,
Fault description
possible cause
702_58300000143607_ara_en_a
Display
Until display is active
P1:Errors is shown / last occurred error code is
displayed
Display is active
P:01 is shown, LED Start/Pause is flashing
P:02 is shown, LED Start/Pause is flashing
P:03 is shown, LED Start/Pause is flashing
P:04 is shown, LED Start/Pause is flashing
P:05 is shown, LED Start/Pause is flashing
P:06 is shown, LED Start/Pause is flashing
P:07 is shown, LED Start/Pause is flashing
P:08 is shown, LED Start/Pause is flashing
P:09 is shown, LED Start/Pause is flashing
P:12 is shown, LED Start/Pause is flashing
P:13 is shown, LED Start/Pause is flashing
P:14 is shown, LED Start/Pause is flashing
P:15 is shown, LED Start/Pause is flashing
P:16 is shown, LED Start/Pause is flashing
P:17 is shown, LED Start/Pause is flashing
LED Start/Pause is illuminating
Fault display (see 2.)
Results
Test program
Er:01
Door open
Door switch not actuated
Er:04
Door actuation defective
Triac defective,
Door relay stuck
Er:05
NTC interruption
Cable break,
NTC damaged
Er:06
NTC short circuit
Cable short circuit,
NTC damaged
Er:07
Unexpected heating (temperature
Damaged heater
increase without actuation of heater)
Heater relay stuck
Er:08
Heating time exceeded (heater does
Damaged heater
not switch off)
Heater relay stuck
Er:09
No communication between control
Wire harness
and inverter
Er:11
Water inlet time exceeded
No water within 6min,
Damaged valve,
Er:12
Wire harness,
Blocked hose
Er:13
Pumping time exceeded
Damaged pump,
Wire harness,
Blocked hose
Er:14
Safety level reached
Blocked pump,
Blocked hose,
Damaged valve
Er:17
Aquastop error
Aquastop actuated
Damaged aquastop switch
Wire harness
Er:20
Spin cycle terminated
No communication between control
and inverter,
Unbalance to high
Er:21
Foam detected
Er:22
Frequency synchronisation failure
Weak power supply
between control main
Er:24
Power supply relay to inverter
Power supply relay stuck
damaged
Er:25
Door lock blocked
Door lock coil overheated by
continuously locking / unlocking
dr:01
IGBT short circuit
Damaged inverter control
dr:02
IGBT interruption
Damaged inverter control
dr:06
NTC-relay failure
NTC is to hot
Relay stucked
dr:08
Speedometer failure
Damaged speedometer,
Wire harness
dr:09
Line over voltage error (short)
Weak power supply
dr:10
Power limiter switch off
To heavy load,
Mechanical friction
dr:11
Voltage too low
Weak power supply
dr:15
Power limiter warning
Too heavy load,
Mechanical friction
dr:19
Motor asymmetry error
Motor winding short circuit
dr:20
IGBT power stage short circuit
IGBT short circuit
High current
dr:21
Line over voltage error (long)
Weak power supply
dr:22
IGBT Temperature sensor error
IGBT temperature sensor damaged
- close door,
Normal
- check lock,
- check wire harness
- replace control
Normal
- rectify cable break,
P:16
- replace NTC
- rectify cable short
P:16
circuit,
- replace NTC
- check heater for short
P:16
circuit to earth,
- replace heater
- replace control
- check heater for short
P:16
circuit to earth,
- replace heater
- replace control
- check wire harness
P:04
- check water supply,
P:08,
- check valve,
P:09,
- check wire harness,
P:13
- check hose
- check pump,
P:15
- check wire harness,
- check hose
- check pump,
P:09
- check hose,
- check valve
- Eliminate leaks
P:13
- check aquastop
switch
- check wire harness
- check wire harness,
P:04
- check load
- consult customer
about dosing
- check power supply
Normal
- replace control
P:04
- wait for 3 mins or 30
Normal
mins
- replace inverter
P:04
- replace inverter
P:04
- wait a couple of
P:04
minutes
- replace inverter
P:04
- check speedometer,
P:04
- check wire harness
- check line voltage
P:04
- check load,
P:04
- check oscillating
system,
- check gasket
- check line voltage
P:04
- check load,
P:04
- check oscillating
system,
- check gasket
- replace motor
P:04
- replace inverter
P:04
- wait
- check line voltage
P:04
- change inverter
P:04