Port Interfaces - Cisco MDS 9500 Series Hardware Installation Manual

Cisco systems network device installation guide
Hide thumbs Also See for MDS 9500 Series:
Table of Contents

Advertisement

Supervisor Modules
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Control and Management
The Supervisor-2 modules provide the following control and management features:
Processor
The Supervisor-2 module has a processor running at 1.4 GHz. It contains a PowerPC class processor and
offers the following memory specifications:
Memory
DRAM
1 internal CompactFlash card
1 external CompactFlash slot
1. The card stores software images.
2. The slot is for optional cards to store additional images, and for configuration, debugging, and
3. NA = not applicable.

Port Interfaces

The Supervisor-2 module provides the following port interfaces:
Cisco MDS 9500 Series Hardware Installation Guide
1-18
A redundant central arbiter that provides traffic control and access fairness.
A nondisruptive restart of a single failing process on the same supervisor.
A service running on the Supervisor-2 module keeps track of the high availability policy of each
process and issues a restart when a process fails. The type of restart issued is based on the process's
capability:
Warm or stateful (state is preserved)
Cold or stateless (state is not preserved)
A nondisruptive switchover from the active Supervisor-2 to a redundant standby without loss of
traffic.
If the Supervisor-2 module has to be restarted, then the secondary Supervisor-2 (which is
continuously monitoring the primary) takes over. Once a switchover has occurred and the failed
Supervisor-2 has been replaced or restarted, operation does not switch back to the original primary
Supervisor-2, unless it is forced to switch back or another failure occurs.
syslog information.
RS-232 (EIA/TIA-232) console port with an RJ-45 connection that you can use to:
Configure the Cisco MDS 9500 Series from the CLI
Monitor network statistics and errors
Configure SNMP agent parameters
RS-232 COM1 port with a DB-9 connector, which can be attached to a modem.
Front panel triple speed (10/100/1000) management port with CTS function. This port is used as an
out-of-band management port. There are two LEDs associated with it. The Link LED on the left side
indicates the link status and the Activity LED on the right side blinks when there is traffic going
through this port.
Bytes
1 GB
1
512 MB
2
3
NA