Connecting to the MGMT 10/100 Ethernet Port
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Figure 3-4
To connect the MGMT 10/100 Ethernet port to an external hub, switch, or router, follow these steps:
Connect the appropriate modular cable to the MGMT 10/100 Ethernet port:
Step 1
Connect the other end of the cable to the device.
Step 2
For high availability, connect the MGMT 10/100 Ethernet port on the active Supervisor-1 module and
Note
on the standby Supervisor-1 module to the same network or VLAN. The active supervisor module owns
the IP address used by both of these Ethernet connections. On a switchover, the newly activated
supervisor module takes over this IP address. This process requires an Ethernet connection to the newly
activated supervisor module.
Cisco MDS 9500 Series Hardware Installation Guide
3-8
Connecting to the MGMT 10/100 Ethernet Port on the Supervisor-1 Module for the
Cisco MDS 9500 Series
M G M T 1 0
Use a modular, RJ-45, straight-through UTP cable to connect the MGMT 10/100 Ethernet port to an
Ethernet switch port or hub.
Use a cross-over cable to connect to a router interface.
/1 0 0
Chapter 3
Connecting the Cisco MDS 9500 Series
OL-19587-01