Cisco MDS 9500 Series Hardware Installation Manual page 123

Cisco systems network device installation guide
Hide thumbs Also See for MDS 9500 Series:
Table of Contents

Advertisement

Chapter 2
Installing the Cisco MDS 9500 Series
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Figure 2-24
Caution
c.
Note
d.
If you replaced the standby supervisor module in a switch that has two supervisors and is running Cisco
Step 7
MDS SAN-OS Release 1.2(2a) or earlier, enable the automatic synchronization feature, which is
disabled by default.
Step 8
If you replaced the supervisor in a switch that does not have a second supervisor or is running Cisco
MDS SAN-OS Release 1.3(1) or later or NX-OS Release 4.1(1b), download the configuration from the
server to the nonvolatile memory of the supervisor. Cisco MDS 9000 Family NX-OS Fundamentals
Configuration Guide.
OL-19587-01
Closing the Ejector Levers
Ejector levers flush
with module faceplate
Do not press down too forcefully on the levers because they can bend.
While pressing down, simultaneously close the left and right ejector levers to fully seat the
supervisor module or switching module in the backplane connector. The ejector levers are fully
closed when they are flush with the front of the module.
Ensure the ejector levers are fully closed before tightening the captive screws. Failure to fully
seat the module in the backplane connector can result in error messages.
Tighten the two captive screws on the supervisor module or switching module to 8 in-lb.
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules