Di Diagnosis Operation; Do Diagnosis Operation - Delta Electronics ASDA-AB Series User Manual

Advanced ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 4 Display and OperationASDA-AB Series

4.4.5 DI Diagnosis Operation

Following the setting method in Figure 4.7 can perform DI diagnosis operation (parameter P4-07).
According to the ON and OFF status of the digital inputs DI1 to DI8, the corresponding status will
display on the servo drive LED display. When the segment lit and display on the screen, it means that
the corresponding digital input signal is ON. (Please also refer to Figure 4.7)
Figure 4.7

4.4.6 DO Diagnosis Operation

Following the setting method in Figure 4.8 can perform DO diagnosis operation (parameter P4-09).
According to the ON and OFF status of the digital outputs DO1 to DO5, the corresponding status will
display on the servo drive LED display. When the segment lit and display on the screen, it means that
the corresponding digital input signal is ON. (Please also refer to Figure 4.8)
Figure 4.8
4-10
Revision November 2014

Advertisement

Table of Contents
loading

Table of Contents