condition is detected, the local DSU IV ESP initiates a handshake
routine with the remote unit to determine if the DTE is generating
the constant data pattern or if the network has failed.
Answer Always
If enabled, the answer unit answers any incoming call regardless of
failed conditions.
Weekend Lockout
If enabled, no backup will occur from midnight Friday to midnight
Sunday.
Weekend and daily lockout apply to automatic DBU only. Manual DBU
is not affected. Also, this parameter affects the originate end only. The
answer end remains DBU-capable at all times.
Daily Lockout
Enable/disable the D
H
Lockout Start
Enter the hour that the daily lockout begins and dial backup is
disabled (0 to 23). Only applies if the D
E
Lockout End
Enter the hour that the daily lockout ends and dial backup is
reactivated (0 to 23). Only applies if the D
is E
Auto Restore
Once the DDS circuit is down, the DSU IV ESP remains in backup
until the DDS circuit is active for the length of time specified for the
restore timer. The selection is entered in minutes (up to 255). If set
to 0, the DDS must be restored manually. The factory default setting
is 1
RESTORE TIMER
(0=OFF): __ __ MIN
61204011L1-1
AILY
and D
H
OUR
ISABLE
OUR
.
NABLED
.
NABLED
.
MINUTE
DSU IV ESP User Manual
Chapter 9. Configuring Dial Options
L
specified by the fields E
OCKOUT
.
L
AILY
AILY
NABLE
parameter is
OCKOUT
parameter
L
OCKOUT
9-7