Chapter 1. Introduction
The DSU IV ESP provides both V.35 and EIA-232 electrical and
physical DTE interfaces to accommodate a variety of applications.
To ensure a reliable connection, the unit features an extended
receiver capability which permits operation over long loops (3.4
miles or 5.5 km of 26 AWG at 56 kbps).
The ESP 4-wire SW56 DBU card and the base unit's integrated
SW56 capabilities are compatible with AT&T Accunet and Sprint
SW56 type services. The V.34 DBU card allows switched backup
over the public switched telephone network (PSTN). The ESP ISDN
1B+D card is compatible with National ISDN and supports a U-
interface to the Basic Rate ISDN.
Figure 1-1 shows a typical point-to-point application for the DSU
IV ESP.
B
RIDGE
PCs
L
ocal
A
rea
N
etwork
P
RINTER
S
ERVER
DEDICATED
PRIVATE NETWORK
1-2
/R
OUTER
POWER SUPPLY
DSU III AR
DSU III AR
DSU III AR
DSU III AR
DSU III S4W
SHELF
CONTROLLER
CONTROLLER
RS
RS
RS
RS
RS
CS
CS
CS
CS
CS
TD
TD
TD
TD
TD
RD
RD
RD
RD
RD
CD
CD
CD
CD
CD
ALM
ALM
ALM
ALM
ALM
DTE
DTE
DTE
DTE
DTE
LOOP
LOOP
LOOP
LOOP
LOOP
RDL
RDL
RDL
RDL
RDL
RDL
PTRN
PTRN
PTRN
PTRN
PTRN
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
DIALMATE
DIAL
DIAL
STATUS
CANCEL
TEST
CONFIG
ENTER
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
TEST
TEST
TEST
TEST
TEST
TEST
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
4-wire
SW56
PUBLIC SWITCHED
DIGITAL NETWORK
4-wire
SW56
ENTER
CANCEL
DSU IV ESP

Figure 1-1. Typical Point-to-Point Application for DSU IV ESP

DSU IV ESP User Manual
POWER SUPPLY
DSU III S4W
DSU III S4W
DSU III S4W
DSU III DBU
DSU III DBU
DSU III DBU
DSU III DBU
DSU S2W
DSU S2W
DSU S2W
RS
RS
RS
RS
RS
RS
RS
RS
RS
RS
CS
CS
CS
CS
CS
CS
CS
CS
CS
CS
TD
TD
TD
TD
TD
TD
TD
TD
TD
TD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
CD
CD
CD
CD
CD
CD
CD
CD
CD
CD
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
ALM
DTE
DTE
DTE
DTE
DTE
DTE
DTE
DTE
DTE
DTE
LOOP
LOOP
LOOP
LOOP
LOOP
LOOP
LOOP
LOOP
LOOP
LOOP
RDL
RDL
RDL
RDL
RDL
RDL
RDL
RDL
RDL
RDL
PTRN
PTRN
PTRN
PTRN
PTRN
PTRN
PTRN
PTRN
PTRN
PTRN
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
ERROR
S
16 S
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
TEST
MART
7
8
9
10
11
12
13
14
15
16
V.34
ISDN
PUBLIC SWITCHED
NETWORK
TELEPHONE NETWORK
V.34
DSU IV ESP
C
A
B
C
1
2
3
D
E
F
4
5
6
7
8
9
SHIFT
QUICK
*
0
#
B
RIDGE
HELF
P
RINTER
PCs
L
ocal
A
rea
N
etwork
/R
OUTER
S
ERVER
61204011L1-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

1204011l1

Table of Contents