Checking the JumboTron Display Unit Functions
Checking the revised light emission data of each dot, HV current value
of a unit or a defictive cell (Revise Data Menu)
1
Select "Revise Data" from the UNIT CONTROL menu.
The "Revise Data Menu" appears in the display window.
2
Press the ◊ or √ button to select the item you want to change. Then
change the data with the ∫ or ı button, and press the ENTER button.
Unit type
JTU-35
Mode
SCREEN No.
UNIT Address
JTU-17
Mode
SCREEN No.
UNIT Address
LDU-15
Mode
SCREEN No.
UNIT Address
3
Press the ∫ or ı button to select the position of the cell or pixel to be
checked. See "Numbering the position of a cell (pixcel)" on page 21.)
34
U N I T C O N T R O L
R e v i s e D a t a M e n u
Mode to be checked
M o d e : P W M
Screen number to be checked
S C R E E N N o : - -
U N I T A d d r e s s : 0 1
Unit number to be checked
H : 0 4
V : 0 3
(Number set on the switch on the
rear of the unit)
U N I T T Y P E : J T U - 3 5
Meaning
Item
PWM: to check the revised pulse width data for the
basic clock
G1V: to check the revised data of voltage applied to
each cell
CELL Down: to check for defective cells in a specified
unit
Ip: to check the HV (High Voltage) current value of a
specified unit
Specifies the screen you want to check
("SCREEN No: all" is displayed automatically. You
cannot change this item.)
Specifies the setting number of the switch on the rear
of the unit to be checked (1-96)
G1V: to check the revised data of voltage applied to
each cell
REF: to check the standard voltage applied to each
cell
CELL Down: to check for defective cells in a specified
unit
Ip: to check the HV (High Voltage) current value of a
specified unit
Specifies the screen you want to check
Specifies the setting number of the switch on the rear
of the unit to be checked (1-48)
If-Data: to check the revised data of voltage applied to
each cell
If-Range: to check the range of current applied to
each cell
Specifies the screen you want to check
Specifies the setting number of the switch on the rear
of the unit to be checked (1-48)
U N I T C O N T R O L
R e v i s e D a t a M e n u
M o d e : P W M
S C R E E N N o : - -
U N I T A d d r e s s : 0 1
H : 0 4
V : 0 3
U N I T T Y P E : J T U - 3 5
4
Press the ENTER button.
The data of the selected mode appear in the display window. For
details, see the respective item below.
5
To check other modes or those for other units, press the ENTER button
again and repeat steps 2 to 4.
6
Press the UNIT CONTROL button to finish checking.
If the selected unit number does not exist or the
communication is not carried out correctly
The "Communication Error!" appears in the display window instead of the
data of the selected mode. Check the cause and try to repeat the steps
above.
To check the revised light emission data of each dot
The light emission data of each dot in a JumboTron display unit are
adjusted to light evenly. You can check the revised data of each dot in the
display window.
In step 2 on page 34, set "SCREEN No. (JTU-17, LDU-15 only)" and
"UNIT Address," then select one of the following modes.
JTU-35
PWM: The revised pulse width data of each dot for the selected position
are displayed.
G1V: The revised voltage data of each cell are displayed.
Cell number (vertical)
Dot number (1–4)
1
2
3
4
B
1 F
1 F
1 F
1 F
1 R
1 F
1 F
1 F
1 F
G
1 F
1 F
1 F
1 F
B
1 F
1 F
1 F
1 F
2 R
1 F
1 F
1 F
1 F
G
1 F
1 F
1 F
1 F
B, R, G
Data of each dot
Cell number (horizontal)
G 1
1
2
3
4
1
F F
F 3
F 7
E 4
2
9 A
A B
B 5
C B
3
C 0
D 7
F 7
D D
Data of each cell
35