Compaq Evo D300 Troubleshooting Manual page 52

Evo desktop and workstation family
Hide thumbs Also See for Evo D300:
Table of Contents

Advertisement

Post Error Messages
Numeric Codes and Text Messages
Code/Message
102-System
Board Failure
103-System
Board Failure
150-SafePost
Active
162-System
Options Not Set
*L = Long, S = Short
A–2
Beeps
Probable Cause
None
DMA, timers, and so
forth.
None
DMA, timers, and so
forth.
None
A PCI expansion card
is not responding.
2S*
Configuration incorrect.
RTC (real-time clock)
battery may need to
be replaced. Battery
life is approximately
3–5 years.
Recommended Action
1. Clear CMOS.
2. Remove expansion boards.
3. Replace the system board.
1. Clear CMOS.
2. Remove expansion boards.
3. Replace the system board.
1. Restart the computer.
2. Disable SafePost.
3. If the expansion card
does not respond, replace
the card.
Run Computer Setup.
Reset the date and time under
Control Panel. If the problem
persists, replace the RTC
battery. See the Hardware
Reference Guide for
instructions on installing a new
battery, or contact your Compaq
authorized dealer or reseller for
RTC battery replacement.