1. INTRODUCTION
1.9

How to Select Sensor Settings

This ECDIS system accepts navigation data input two ways: System or Local. System
shares sensor data among multiple ECDIS in the network. Sensor priority is also com-
monly shared among the ECDIS. Local selects a sensor outside the network.
1. Right-click anywhere in the [Sensor infor-
mation] box to show the context-sensitive
menu.
2. Click [Local] or [System] as applicable.
Note: Sensor system can also be selected
from the menu. Open the menu and click
[System/Local Select] on the [Sensor]
menu. Click the circle next to [System Sen-
sor] or [Local Sensor] as appropriate then
click the [Save] button.
1.10

How to Enter Ship Speed

The speed can be entered from a log (STW) or GPS (SOG), or manually on the menu.
Note that FURUNO GPS Navigator GP-150 provides both COG and SOG.
Speed data is checked for integrity (see section 18.7 for details), and the data is
judged as Passed, Doubtful or Failed. The results of the check appear on the [SPD]
page, shown below.
Passed (green): Data is available for comparison and data is normal.
Doubtful (yellow): Data is not available for comparison, but data is normal.
Failed (red): Data may or may not be available for comparison, and data is abnormal.