200-xx
Invalid memory configuration
201-xx
Memory machine ID test failed
202-xx
Memory system ROM checksum
failed
203-xx
Memory write/ read test failed
204-xx
Memory address test failed
206-xx
Increment pattern test failed
210-xx
Random pattern test failed
Return to top
Keyboard Error Codes
Error Code: Description:
301-xx
Keyboard short test, 8042 self-test
failed
302-xx
Keyboard long-test failed
303-xx
Keyboard LED test, 8042 self-test
failed
304-xx
Keyboard typematic test failed
Return to top
Verify
memory module
1.
compatibility.
Reinsert memory in the correct
2.
location.
The following steps apply to error codes
201-xx and 202-xx:
Flash the ROM and retest.
1.
Replace the memory and retest.
2.
Replace the
system board
3.
retest.
The following steps apply to error codes
203-xx through 210-xx:
Remove one
memory module
1.
time until the error message
stops.
Replace other removed modules
2.
one at a time, testing each to
ensure the error does not return.
Replace the
system board
3.
retest.
Recommended Action:
The following steps apply to error codes
301-xx through 304-xx:
Check the keyboard connection. If
1.
disconnected, turn the computer
off and connect the keyboard.
Replace the keyboard and restart.
2.
Replace the
system board
3.
retest.