Mitsubishi Electric MELSERVO MR-J4-B-LL Series Instruction Manual page 61

General-purpose ac servo
Table of Contents

Advertisement

3. PARAMETERS
No.
Symbol
PT13
*TOP2
Function selection T-2
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PT14
*TOP3
Function selection T-3
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PT21
AFBO
Pressure feedback offset
Set the pressure feedback offset voltage.
When "100" is set, the voltage is compensated by -100 mV.
When "-100" is set, the voltage is compensated by +100 mV.
PT22
AFBD
Pressure feedback unit constant
Set the conversion coefficient of the pressure feedback voltage to be returned to the
controller.
Set a pressure feedback value to be returned to the controller at the maximum input voltage
(10 V) of AD0 (Pressure feedback).
PT23
AO1
Analog monitor input 1 offset
Set the offset voltage of the analog monitor input 1.
When "100" is set, the voltage is compensated by -100 mV.
When "-100" is set, the voltage is compensated by +100 mV.
PT24
AD1
Analog monitor input 1 unit constant
Set the conversion coefficient of the analog monitor input 1 voltage returned to the controller.
Set the value of the analog monitor 1 to be returned to the controller at the maximum input
voltage (10 V) of AD1 (Analog monitor input 1 voltage).
PT25
AO2
Analog monitor input 2 offset
Set the offset voltage of the analog monitor input 2.
When "100" is set, the voltage is compensated by -100 mV.
When "-100" is set, the voltage is compensated by +100 mV.
PT26
AD2
Analog monitor input 2 unit constant
Set the conversion coefficient of the analog monitor input 2 voltage returned to the controller.
Set the value of the analog monitor 2 to be returned to the controller at the maximum input
voltage (10 V) of AD2 (Analog monitor input 2 voltage).
Name and function
Explanation
Pressure control command compensation
Enable/disable the pressure control command compensation.
0: Disabled (A command from the controller will be immediately
reflected.)
1: Enabled (A command from the controller will be compensated
and then reflected.)
Speed limit command compensation
Enable/disable the speed control command compensation in the
pressure control.
0: Disabled (A command from the controller will be immediately
reflected.)
1: Enabled (A command from the controller will be compensated
and then reflected.)
For manufacturer setting
Explanation
A function that clears the integration when the pressure control
command is "0"
0: Disabled
1: Enabled
For manufacturer setting
3 - 16
Initial
Setting
value
range
[unit]
Refer to the Name
and function
Initial
column.
value
0h
0h
0h
0h
Refer to the Name
and function
Initial
column.
value
0h
0h
0h
0h
0
-9999
[mV]
to
9999
20000
500
to
[Command
unit]
30000
0
-9999
[mV]
to
9999
20000
500
to
[Command
30000
unit]
0
-9999
[mV]
to
9999
20000
500
to
[Command
unit]
30000