3. PARAMETERS
3.1.8 Pressure control parameters ([Pr. PT_ _ ])
No.
Symbol
PT01
APA
Pressure loop gain
PT02
AIA
Pressure integral compensation
PT03
ADA
Pressure incomplete integral coefficient
PT04
For manufacturer setting
PT05
PT06
PT07
PT08
PT09
PT10
PT11
PT12
*TOP1
Function selection T-1
PT13
*TOP2
Function selection T-2
PT14
*TOP3
Function selection T-3
PT15
For manufacturer setting
PT16
PT17
PT18
PT19
PT20
PT21
AFBO
Pressure feedback offset
PT22
AFBD
Pressure feedback unit constant
PT23
AO1
Analog monitor input 1 offset
PT24
AD1
Analog monitor input 1 unit constant
PT25
AO2
Analog monitor input 2 offset
PT26
AD2
Analog monitor input 2 unit constant
PT27
ADF
Analog monitor input filter setting
PT28
For manufacturer setting
PT29
PT30
PT31
PT32
PT33
PT34
PT35
PT36
PT37
PT38
PT39
PT40
PT41
PT42
PT43
PT44
PT45
PT46
PT47
PT48
Name
3 - 10
Control mode
Initial
Unit
value
800
75
[ms]
10000
0
0.0
800
75
10000
800
75
10000
0000h
0000h
0000h
0000h
0000h
0
0
0
0000h
0
[mV]
20000
[Command
unit]
0
[mV]
20000
[Command
unit]
0
[mV]
20000
[Command
unit]
0000h
0
24.0
0
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h