Mitsubishi Electric MELSERVO MR-J4-B-LL Series Instruction Manual page 19

General-purpose ac servo
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
Model MR-J4-_-LL
Ambient
temperature
Ambient
humidity
Environment
Ambience
Altitude
Vibration resistance
Mass
Note 1. 0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifiers, operate them at the ambient temperatures of 0 °C to 45 °C or at 75% or smaller
effective load ratio.
3. Test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuit to
self-diagnose.
4. The communication cycle depends on the controller specifications and the number of axes connected.
5. Follow the restrictions in section 2.7 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction Manual" when using the servo amplifiers
at altitude exceeding 1000 m and up to 2000 m above sea level.
10B1
Operation
Storage
Operation
Storage
[kg]
20B1
0 °C to 55 °C (non-freezing)
-20 °C to 65 °C (non-freezing)
90 %RH or less (non-condensing)
Indoors (no direct sunlight),
free from corrosive gas, flammable gas, oil mist, dust, and dirt
2000 m or less above sea level (Note 5)
5.9 m/s
2
, at 10 Hz to 55 Hz (directions of X, Y and Z axes)
0.8
1 - 8
40B1
1.0