1.2.13.

TABLETOP HEIGHT AND TILTING WITH JOYSTICK

23 Table height UP movement
24 Table height DOWN movement
25 Trendelenburg (negative) tilting
26 Positive (to vertical position) tilting
1.2.14.

TABLETOP RESET BUTTON

27 Table horizontal stop
1.2.15.

EXPOSURE CONTROLS

28 Preparation (1st trigger) control
29 X-ray emission (2nd trigger) control
Radiography can be also performed by pressing the pedal indicated by the symbol
(1st trigger) and X-ray emission control (2
Fluoroscopy is performed by pressing the pedal indicated by the symbol
Cine mode is performed by pressing the pedal indicated by the symbol
please refer to the user manual of digital system).
X-RAY EQUIPMENT IS DANGEROUS TO BOTH PATIENT AND OPERATOR UNLESS MEASURES OF PROTECTION ARE STRICTLY
X-ray equipment if not properly used may cause injury. Accordingly, the instructions herein should be thoroughly read and understood
before attempting to place this equipment in operation. We will be glad to assist and cooperate in placing this equipment in use.
Although this apparatus is built to the highest safety standards and incorporates a high degree of protection against X-radiation other than the useful
beam, no practical design of equipment can provide complete protection. Nor can any practical design compel the operator to take adequate
precautions to prevent the possibility of any persons carelessly, unwisely, or unknowingly exposing themselves or others to X-radiation.
It is important that everyone working with X-radiation be properly trained and take adequate steps to insure protection against injury. The manufacturer
assumes that all operator and service personnel authorized to use, install, calibrate and maintain this equipment is cognizant of the danger of
excessive exposure to X-radiation, is sufficiently trained and has the required knowledges for it. The equipment herein described is sold with the
understanding that the manufacturer, its agents, and representatives are not liable for injury or damage which may result from exposure to X-radiation.
Various protective material and devices are available. It is recommended that such materials and devices be used.
Digital Remote Controlled Table with dynamic flat panel detector
nd
trigger) as for standard protocols with two buttons on the table console.